Connections

Modes Of Operation
The LD-200 series detector may be configured for any one of the following modes:
| Presence Mode |
Pulse Mode |
| AB Logic Presence Mode(Barrier Operation) |
AB Logic Pulse Mode(Counting Logic) |
Indicates And Switch
❀Power Led: RED Power LED Indicates “Power ON”
-
CH1 Detecting Led:Continuously On: Indicates vehicle detection.
-
Blinking Slowly: Indicates loop is short circuit or the number of twists after the loop is not enough.
-
Blinking Fast: Indicates loop is open circuit or too many twists after the loop.
-
CH2 Detecting Led:Continuously On: Indicates vehicle detection.
-
Blinking Slowly: Indicates loop is short circuit or the number of twists after the loop is not enough.
-
Blinking Fast: Indicates loop is open circuit or too many twists after the loop.
❀Sensitivity Selection
-
Sensitivity and frequency of the loop can be adjusted by 7-way dip switch and 10-way dip switch setting.
-
User can select 8 different setting by changing the setting of the dip-switch to different modes as in the dip-switch setting tables below. Dip switch 6, 7 and 8 for CH1 sensitivity selection with 0.8 being the least sensitive and 0.015 being the most sensitive.
-
Dip switch 3, 4 and 5 for CH2 sensitivity selection with 0.8 being the least sensitive and 0.015 being the most sensitive.

❀Switch1=S1:Channel 1 Loop Function Selection (10 Way Dip Switch)

-
(Switch1=S1)D3,D4,D5 and(Switch2=S2)D1,D2 Setting Special Functions(Mode1,2,3 Direction Detection. Mode4,5,6 Normal mode, two loop detection are separated.)



Reset Button: Please note: The LD-200 must be reset every time a setting change is made to the Dip switches.
Loop Installation
The loops are sealed using a “quick-set” black epoxy compound or hot bitumen mastic to blend with the roadway surface.
When installation, please keep the product plug and socket in the vertical direction
Troubleshooting

Product Series
| LD-100 |
LD-102 |
LD-200 |
LD-202 |
JTHT-11 |
|

Single Channel
100-240 V AC
|

Single Channel
12-24 V AC/DC
|

Dual Channel
100-240 V AC
|

Dual Channel
12-24 V AV/DC
|

Loop cable
305 m Teflon coil
|
| LCR-MT |
|
|
|
|
|

Multimeter
|
|
|
|
|