10KW AC Three-Phase Load Bank 380V Adjustable Power Resistor For Generator, Inverter, And Energy Systems
The 10KW AC Three-Phase Load Bank 380V is an efficient, reliable and versatile load test device designed for three-phase power systems and widely used for load testing in power companies, data centers, generator sets and other industrial fields.
Product features
10KW AC Three-Phase Load Bank 380V can provide users with 10KW continuous load test capacity, which is widely used in the test of power companies, generator sets, UPS power supplies and other equipment.
Precise resistance control
The load bank uses a resistance accuracy of ±3% to ensure high-precision load simulation during testing and ensure that users can obtain reliable test data. This precise control is essential to ensure the stability and efficiency of the power system.
Forced air cooling system
To ensure stable operation at high loads over long periods of time, the 10KW AC Three-Phase Load Bank 380V is equipped with a forced-air cooling system using six model 12038 fans to provide effective cooling capacity.
Digital display
10KW AC Three-Phase Load Bank 380V is equipped with a digital display function, which can display voltage, current and power data in real time, so that users can monitor various parameters during the test in real time. This display mode greatly improves the convenience of operation and the accuracy of test.
| Model number | JH-RYF-10KWA380-W12K | |||||
| brand | Jianhong | |||||
| Dimension | ≤670*250*730MM(L*W*H) | |||||
| Weight | 31.2KG | |||||
| Rated voltage | AC380V Three-phase four-wire | |||||
| Rated power | 10KW | |||||
| Auxiliary power supply |
AC220V ~AV230V 50/60HZ | |||||
| Power factor | 1 | |||||
| Resistance accuracy | ±3%(Sheet resistor) | |||||
| Cold pass | Forced air cooling, left to right, 12038 fans - 6 (DC12V) | |||||
| Working environment | Working temperature: -10~50℃, dry and ventilated | |||||
| Control mode | Air switch + contactor | |||||
| Class of protection | IP20 (indoor) | |||||
| Display mode | Digital display voltage, current, power | |||||
| Power gear | 10W,20W,20W,50W,100W,200W,200W,400W,1KW,2KW,3KW,3KW | |||||
| Step accuracy | 10W(Three-phase power) | |||||
| Loading mode | Three-phase simultaneous loading | |||||
| Load protection | Overheat alarm, overvoltage protection, emergency stop optional | |||||
| Working mode | Can work continuously online, 7*24 working system, warranty 1 year | |||||
| Output mode | 1 set of resistance outlets (threaded terminals) +1 set of auxiliary power supplies (standard power outlets) | |||||
| Mobile mode | Portable + universal wheel | |||||
Generator Set test : Used to test the load of the generator set to ensure the stability and reliability of the generator set under real workload.
Power companies : Used for load simulation of power systems, testing the performance of power equipment.
Data Center : Simulates the operation of the power system under heavy load to ensure the normal operation of the power equipment in the data center.
UPS Power test : Used to load test the UPS system to verify its performance and stability in emergency situations.
Industrial Equipment: Testing large power equipment and power systems in industrial facilities to ensure load capacity and safety.