Product features
Single-component, neutral curing;
Excellent mechanical properties;
Excellent resistance to weathering and resistance to high/low temperatures;
Excellent adhesion to most building materials, and generally no need for primer.
Main purpose
Structural bonding and sealing for glass, aluminum panels, clay tile panels, curtain wall systems and metal structures;
Many other structural applications in buildings
Usage restrictions
1.It is not suitable for all materials that secrete oils, plasticizers or solvents;
2.It cannot be used on surfaces that are frosted or damp;
3.It is not suitable for places where materials are continuously immersed in water or where they are constantly damp throughout the year;
4.When the surface temperature of the material is lower than 4℃ or higher than 50℃, construction is not advisable.
enforce standards
| Test Item | Condition | Technical Requirement | Typical Value | Test Standard |
|---|---|---|---|---|
| Sagging | Vertical | ≤ 3 mm | 0 mm | GB/T 13477.6 |
| Sagging | Horizontal | No Deformation | No Deformation | GB/T 13477.6 |
| Extrudability | — | ≤ 10 s | 2.0 s | GB 16776 |
| Tack Free Time | — | ≤ 3 h | 0.5 h | GB/T 13477.5 |
| Shore A Hardness | — | 20–60 | 45 | GB/T 531.1 |
| Tensile Adhesion Strength | 23°C | ≥ 0.6 MPa | 1.22 MPa | GB 16776 |
| Tensile Adhesion Strength | 90°C | ≥ 0.45 MPa | 1.00 MPa | GB 16776 |
| Tensile Adhesion Strength | -30°C | ≥ 0.45 MPa | 1.76 MPa | GB 16776 |
| Tensile Adhesion Strength | After Water Immersion | ≥ 0.45 MPa | 1.14 MPa | GB 16776 |
| Tensile Adhesion Strength | After Water and UV Exposure | ≥ 0.45 MPa | 1.07 MPa | GB 16776 |
| Adhesion Failure Area | — | ≤ 5% | 0% | GB 16776 |
| Elongation at Maximum Tensile Strength | — | ≥ 100% | 287% | GB 16776 |
| Heat Aging Weight Loss | — | ≤ 10% | 2.0% | GB 16776 |
| Heat Aging | Cracking | None | None | GB 16776 |
| Heat Aging | Powdering | None | None | GB 16776 |
FAQ