Specifications
Brand Name :
ITI -LINK
Model Number :
ITI-CTSF6A-018
Certification :
UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
Place of Origin :
Shenzhen
MOQ :
1000pcs
Payment Terms :
T/T
Supply Ability :
2000pcs/day
Delivery Time :
15-45 Days
Packaging Details :
Inner box size: 32 cm (length) × 32 cm (width) × 18.5 cm (height) Outer box size (for packing): 39 cm (length) × 33.5 cm (width) × 34 cm (height)
Category :
CAT6A
Operating Temperature :
-20°C to 60°C
Jacket Material :
PVC (Polyvinyl Chloride)
Color :
Purple
Bandwidth :
500 MHz
Conductor Material :
Copper
Length :
500feet
Shielding Type :
SFTP (Shielded Foiled Twisted Pair)
Description

CAT6A SFTP Cable LSZH Shielded Bulk LAN Cable For Data Center Business Industrial Networking


Product Description:

The INTEGRITY ITI-CTSF6A-018 CAT6A SFTP LSZH purple cable is engineered for wholesale buyers and system integrators who demand industrial-grade Ethernet performance. With 23AWG solid copper conductors, dual-layer shielding, and a LSZH purple jacket, it guarantees 10Gbps speed at 550MHz bandwidth while ensuring fire safety and EMI resistance. Offered in bulk reels for contractors and data centers, it delivers long-term reliability and cost efficiency.

  • Bulk 23AWG solid copper construction ensures stable signal integrity.

  • S/FTP shielding design protects against cross-talk, EMI, and interference.

  • 550MHz bandwidth supports 10GBASE-T, 25GBASE-T, and 50GBASE-T future networks.

  • Low-smoke LSZH purple jacket complies with global building safety codes.

  • Optimized for data center rack cabling and industrial plant backbones.

  • Durable jacket withstands UV, temperature fluctuations, and chemical exposure.

  • Easy-to-identify purple color speeds up cable management by 30%.

  • Certified by UL, CE, RoHS, and CPR Dca-S2/D2/A1 standards.

  • Volume discounts up to 25% available for 500+ reel orders.

  • Custom lengths, branding, and packaging services for bulk buyers.


Technical Parameters:

Product Description:

CAT6A SFTP Cable LSZH Shielded Bulk LAN Cable For Data Center Business Industrial Networking

Rev.: A ECN Description:
Construction Item Description Electrical Property


Conductor


Material

Bare Solid Copper(elongation:

19-24%)

Conductor Resistance at 20°C ≤ 9.5 Ω / 100m
OD 23 AWG Resistance unbalance within a pair ≤ 2%






Insulation

Material


PE Skin-Foam-Skin

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V


>1500 MΩ / 100m

OD 1.35 ±0.01 mm Mutual capacitance 5600 pF / 100m MAX
Average THK 0.38 mm Capacitance unbalance pair to ground at 800Hz or 1 kHz ≤ 160 pF / 100m



Color

1p: white + 2 blue stripes & blue Characteristic impedance at 100MHz 100 ± 15 Ω
2p: white + 2 orange stripes & orange

Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

0.7 KV AC for 1 min


No breakdown

3p: white + 2 green stripes & green Mechanical Property
4p: white + 2 brown stripes & brown



insulation

elongation before aging ≥ 300%



Pair Twist



Lay & Direction

1p: S=19.0 mm (27%) tensile strength before aging ≥12 MPa
2p: S=23.5 mm (35%) elongation after aging ≥ 150 %
3p: S=21.5 mm (31%) tensile strength after aging ≥10.5 MPa
4p: S=27.0 mm (40%)



jacket

elongation before aging ≥ 125 %
OD / tensile strength before aging ≥ 10 MPa


Inner Assemble

Lay S=90 ± 5 mm elongation after aging ≥ 100 %
Direction according to the drawing tensile strength after aging ≥ 8 MPa
Filler / Packing
OD / Drum NA



Shield

Shield Pair Shield

Construction /
Material Aluminium (PET/ALU)
Coverage ≥ 115%
Braid Material ɸ 0.12mm Aluminum-magnesium braided
Coverage ≥ 40%





Jacket

Material LSZH, 60P, -20~75℃
Hardness 81± 3
OD 7.5 ± 0.2
Average THK 0.60 ~ 0.70


Color

Purple
Marking Color black
Marking

according to the customer's

requirements



Transmission Properties
CAT6A ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013



No.


Frequency


Attenuation (Max)

Propagation Delay

(Max)

Propagation Delay Skew

(Max)


Return Loss (Min)


NEXT (Min)


PS NEXT (Min)


EL-FEXT (Min)


PS EL-FEXT (Min)


MHz dB/100m ns/100m ns/100m dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m)
1 4 3.8 552 45 23.01 66.27 63.27 55.96 52.96
2 8 5.31 546.73 45 24.52 61.75 58.75 49.94 46.94
3 10 5.93 545.38 45 25 60.3 57.3 48 45
4 16 7.49 543 45 25 57.24 54.24 43.92 40.92
5 20 8.38 542.05 45 25 55.78 52.78 41.98 38.98
6 25 9.38 541.2 45 24.32 54.33 51.33 40.04 37.04
7 31.25 10.5 540.44 45 23.64 52.88 49.88 38.1 35.1
8 50 13.36 539.09 45 22.21 49.82 46.82 34.02 31.02
9 62.5 14.99 538.55 45 21.54 48.36 45.36 32.08 29.08
10 100 19.13 537.6 45 20.11 45.3 42.3 28 25
11 125 21.51 537.22 45 19.43 43.85 40.85 26.06 23.06
12 200 27.58 536.55 45 18 40.78 37.78 21.98 18.98
13 250 31.07 536.28 45 17.32 39.33 36.33 20.04 17.04
14 300 34.27 536.08 45 17.3 38.14 35.14 18.46 15.46
15 350 37.25 535.92 45 17.3 37.14 34.14 17.12 14.12
16 400 40.05 535.8 45 17.3 36.27 33.27 15.96 12.96
17 450 42.71 535.7 45 17.3 35.5 32.5 14.94 11.94
18 500 45.26 535.61 45 17.3 34.82 31.82 14.02 11.02



Applications:

The INTEGRITY ITI-CTSF6A-018 CAT6A SFTP Ethernet cable is engineered for high-performance networking in mission-critical environments. Featuring 23AWG solid copper conductors, double shielding (foil and braid), and a low smoke zero halogen (LSZH) purple jacket, this cable delivers reliable 10Gbps data transmission up to 100 meters with 500MHz bandwidth.

  • Data Centers and Cloud Facilities – This bulk 1000ft CAT6A SFTP LSZH Ethernet cable is optimized for high-density server racks, backbone cabling, and cloud storage networks. Its superior shielding minimizes electromagnetic interference, making it the ideal choice for hyperscale data centers and financial trading hubs requiring low latency and maximum reliability.
  • Enterprise and Commercial Networks – Designed for structured cabling projects, this shielded CAT6A SFTP cable supports business offices, universities, hospitals, and government facilities. The LSZH jacket ensures compliance with EU CPR fire safety regulations, making it safe for modern workplaces and smart buildings.
  • Industrial and Manufacturing Applications – In factories, 5G base stations, and automation systems, this heavy-duty CAT6A SFTP cable supports stable connectivity for PLCs, industrial robots, IP surveillance cameras, and wireless access points. Its 23AWG solid copper design ensures low signal loss, long-distance stability, and compatibility with PoE/PoE+.
  • Smart Infrastructure and IoT – This purple LSZH Ethernet cable is also widely used in smart homes, IoT device integration, and AI computing clusters, providing a reliable backbone for intelligent networks.

For bulk projects, contractors, and wholesale buyers, INTEGRITY offers OEM/ODM customization, volume discounts, and staggered delivery options. With advanced production capacity and CNAS-certified lab testing, INTEGRITY guarantees consistent quality and long-term reliability.


CAT6A SFTP Cable LSZH Shielded Bulk LAN Cable For Data Center Business Industrial Networking

Send your message to this supplier
Send Now

CAT6A SFTP Cable LSZH Shielded Bulk LAN Cable For Data Center Business Industrial Networking

Ask Latest Price
Brand Name :
ITI -LINK
Model Number :
ITI-CTSF6A-018
Certification :
UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
Place of Origin :
Shenzhen
MOQ :
1000pcs
Payment Terms :
T/T
Contact Supplier
CAT6A SFTP Cable LSZH Shielded Bulk LAN Cable For Data Center Business Industrial Networking
CAT6A SFTP Cable LSZH Shielded Bulk LAN Cable For Data Center Business Industrial Networking
CAT6A SFTP Cable LSZH Shielded Bulk LAN Cable For Data Center Business Industrial Networking
CAT6A SFTP Cable LSZH Shielded Bulk LAN Cable For Data Center Business Industrial Networking

Integrity Cable Co., Limited

Verified Supplier
2 Years
shenzhen
Since 2014
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter, Seller
Total Annual :
100,000,000-150,000,000
Employee Number :
100~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement