Specifications
Brand Name :
E+H
Model Number :
92F25-DSKA1AA0A4AW
Certification :
CE
Place of Origin :
Germany
MOQ :
1
Price :
USD3600
Payment Terms :
T/T
Delivery Time :
4-8weeks
Packaging Details :
ORIGINAL
Description

E+H Flowmeter 92F25-DSKA1AA0A4AW

Detailed Parameters, Functions & Application Scenario Analysis

1. Model Code Interpretation: 92F25-DSKA1AA0A4AW

Series: Proline Prosonic Flow 92F In-line Ultrasonic Flowmeter, 2-wire loop-powered type
Nominal Diameter: DN25 (1 inch)
Code definition:
  • D: 3-beam measurement design with strong anti-interference performance and short straight pipe requirement
  • S: Wetted part material: CF3M (316Ti stainless steel)
  • K: Process connection: PN40 pressure rating, 316L flange connection
  • A: Standard factory calibration
  • 1: Basic certification
  • A: Integrated aluminum housing, IP67 protection grade
  • 0: No separate signal cable equipped
  • A: M20 cable gland entry
  • 4: Dual-line backlit LCD display with local operation keys, built-in HART protocol
  • A: Factory default configuration, basic software version
  • W: Output signals: 4-20mA HART + pulse/status output

2. Core Technical Parameters (DN25)

Measurement Performance

  • Measuring principle: Time-difference ultrasonic technology, full bore design
  • Flow velocity range: 0.5 ~ 10 m/s
  • Volumetric flow range (DN25): 0 ~ 17.7 m³/h
  • Basic accuracy: ±0.5% of reading; optional high precision ±0.3% of reading (velocity>0.5 m/s)
  • Repeatability: ±0.2% of reading

Process Operating Conditions

  • Medium temperature range: -40℃ ~ +150℃ (extended version up to 200℃ available)
  • Rated working pressure: PN40 (40 bar), compatible with ASME Class300
  • Wetted material: 316L / CF3M stainless steel
  • Explosion-proof certification: ATEX, IECEx, FM, CSA, NEPSI (China Ex certification)
  • Protection class: IP67 / NEMA 4X

Electrical & Communication Specifications

  • Power supply: 2-wire loop-powered via 4-20mA loop, no independent external power required
  • Signal output: 4-20mA analog, pulse output, status switch output
  • Communication protocol: HART; expandable to PROFIBUS PA / FOUNDATION Fieldbus
  • Human-machine interface: Dual-line backlit LCD display, on-site key configuration

3. Main Functions

  1. Compatible with both conductive and non-conductive liquids, applicable for oil products, organic solvents and low-conductivity media which electromagnetic flowmeters cannot measure
  2. 3-beam sensing structure, only 3D upstream straight pipe required, ideal for limited installation space
  3. Full straight-through bore structure with zero pressure loss, energy-saving operation, free from clogging risk, suitable for media with tiny solid particles and fibers
  4. Built-in intelligent diagnostic function: air bubble detection, scaling & corrosion monitoring, sensor self-verification and automatic data backup
  5. Simplified wiring design with 2-wire system, support remote parameter configuration and data monitoring via HART communication

4. Typical Application Scenarios

Chemical & Petrochemical Industry (Most Recommended)

Organic solvents such as methanol, ethanol, and aromatic hydrocarbons; hydrocarbon oil products including gasoline, diesel oil and crude oil; high-purity water, deionized water, boiler feed water, ethylene glycol and dilute acid-base solution.

Oil & Gas and Power Industry

Oilfield water injection, finished oil pipeline transportation; power plant circulating water, condensed water and chemical dosing system; hydraulic oil and lubricating oil flow measurement.

Pharmaceutical & Fine Chemical Industry

WFI water for injection, pure steam condensate, solvent recovery process and batching control of reactor raw materials.

Water Treatment & General Utilities

Industrial softened water, boiler make-up water, cooling tower circulating water, low-solids wastewater, central air-conditioning chilled water and heating hot water.

Not Recommended Application Conditions

Media with high solid content and severe abrasion such as slurry and mud; highly corrosive strong acid & alkali liquid; gas and steam medium (this model is exclusively for liquid measurement).

5. Comparative Selection Advantages

  • vs Electromagnetic Flowmeter: Supports non-conductive liquid measurement, wider temperature resistance and zero pressure loss
  • vs Coriolis Mass Flowmeter: More cost-effective, simple 2-wire wiring, easy on-site installation
  • vs Clamp-on Ultrasonic Flowmeter: Higher measuring accuracy and better long-term operational stability

6. Summary

Model 92F25-DSKA1AA0A4AW is a DN25 3-beam in-line ultrasonic flowmeter featuring 2-wire HART communication, 150℃ medium temperature resistance and PN40 high pressure resistance. It is the preferred flow measuring instrument for non-conductive liquid, high-purity fluid and oil medium in chemical and petrochemical industries, integrating high precision, zero pressure loss, economical cost and convenient installation.
Send your message to this supplier
Send Now

E+H Flowmeter 92F25-DSKA1AA0A4AW Proline Prosonic Flow 92F In-line Ultrasonic Flowmeter

Ask Latest Price
Brand Name :
E+H
Model Number :
92F25-DSKA1AA0A4AW
Certification :
CE
Place of Origin :
Germany
MOQ :
1
Price :
USD3600
Contact Supplier
E+H Flowmeter 92F25-DSKA1AA0A4AW Proline Prosonic Flow 92F In-line Ultrasonic Flowmeter

GREAT SYSTEM INDUSTRY CO. LTD

Verified Supplier
2 Years
Since 1998
Business Type :
Distributor/Wholesaler
Total Annual :
7000000-10000000
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement