Triplex UD Cable ABC Aerial Bundled Cables 19/33kV Screened MV Cable to IEC 60502
Triplex UD Cable ABC Aerial Bundled Cables 19/33kV Screened cable is primarily used in overhead power distribution networks for transmitting electrical energy. It is designed for aerial installation and is suitable for medium-voltage applications (19kV to 33kV). The cable features a screened design to enhance electromagnetic compatibility and reduce interference. It is commonly employed in urban and rural power grids, industrial plants, and renewable energy projects (e.g., solar or wind farms) where reliable and efficient power transmission is required. The triplex configuration (three conductors bundled together) optimizes space and simplifies installation
| Description | Phase conductor | Bare | Approx.Overall | ||
|
| NO of Stranding& | XLPE | NO of.Stranding & | Diameter | Weight |
| 3×10mm²+10mm² | 7/1.35 | 1.0 | 7 / 1.35 | 14.76 | 160 |
| 3×16mm²+16mm² | 7/1.70 | 1.2 | 7 / 1.70 | 18.28 | 249 |
| 3×25mm²+25mm² | 7/2.22 | 1.2 | 7 / 2.22 | 20.92 | 357 |
| 3×35mm²+35mm² | 7/2.59 | 1.4 | 7 / 2.59 | 24.33 | 499 |
| 3×50mm²+50mm² | 7/3.10 | 1.4 | 7 / 3.10 | 26.97 | 678 |
| 3×70mm²+50mm² | 19/2.22 | 1.4 | 19 / 2.22 | 31.05 | 864 |
| 3×95mm²+50mm² | 19/2.59 | 1.4 | 19 / 2.59 | 34.89 | 1092 |





What is the primary application of 19/33kV triplex UD ABC aerial bundled cables?
Designed for medium-voltage overhead power distribution (19–33kV), commonly used in urban grids, rural electrification, and industrial networks.
Why is the screened design important for these cables?
The screened layer enhances electromagnetic compatibility (EMC) by reducing interference, ensuring stable power transmission.
What conductor materials are used in these cables?
Typically aluminum conductors (stranded or alloyed) for lightweight and high conductivity.
What insulation types are available for this cable?
XLPE (cross-linked polyethylene) or PVC insulation, offering durability and high-temperature resistance.
How does the triplex configuration benefit installation?
Three bundled conductors optimize space, simplify aerial deployment, and reduce maintenance costs.
Are these cables suitable for renewable energy projects?
Yes, they are used in solar/wind farms for reliable medium-voltage power distribution.
What safety features does the screened design provide?
Shields against electromagnetic interference and improves protection against environmental hazards.
Can these cables be used in harsh weather conditions?
Yes, they are designed for outdoor overhead use with weather-resistant insulation and screening.