Commercial Water Ionizer With 2T/H Water Yield Specifications:
Specification | EHM-2000 | |
Working mode | continuous | |
Rated voltage | 220V,50Hz 110V, 60Hz | |
Rated power | 1800W | |
Working condition | Source water | 100mg/L,≥0.3Mpar Municipal water according with national standards Rigidity<100mg/L, water pressure≥0.3Mpar |
Environment | Temperature: 5-40 Humidity:≤85% | |
accelerant | Na LI | |
Quality of outlet water | Acidic oxidation electrode water | pH2.3~2.720~80mg/L ORP≥1100mV PH value:2.3-2.7; percentage of residue chlorine: 20~80mg/L ORP: ≥1100mV |
Alkalescent oxidation electrode water | pH≥11; ORP-450mV | |
Outlet water | Acidic oxidation electrode water | ≥2000L/h |
Alkalescent oxidation electrode water | ≥2000L/h | |
Useful life of electrolyzed slot | ≥2500h | |
Dimension | 700*560*1100mm | |
Net weight | 332Kg | |
Fittings | 1,pH1,1-2,1. 2.A set of chlorine residue, some PH test paper, a inlet chequered hose,two outlet chequered hoses 3. Pre-filtering system |
Industrial Electrolysis Water Device Specification:
Industrial Electrolysis Water Device,low PH value (2.3 or less) and high ORP (+1100 mv or above), beyond the scope of various pathogenic micro-organisms to survive and make cell membrane potential change, leading to cell membrane permeability-increasing and the destruction of cell metabolism enzymes, microbes quickly die. Meanwhile, the acidic electrolyzed oxidizing water and contains 50-80mg / L of chlorine to more effectively kill pathogenic microorganisms.
Application:
(1) can control and prevention of fruits, vegetables and other plants, a variety of diseases, alternative chemical pesticides;
(2) could effectively degrade the surface of plant pesticide residues;
(3) could effectively kill the seeds carried by micro-organisms and fungi;
(4) can be suitably modified alkaline soil.
Storage conditions:
(1) water storage containers to be closed;
(2) to avoid direct exposure to light;
(3) The storage ambient temperature is not greater than 40 ;
Under these conditions, acidic electrolyzed oxidizing water could be stored for at least 90 days.