SUS310S Vertical Muffle Furnace Electric Vacuum Nitrogen Hydrogen Atmosphere
Product Attributes
| Attribute | Value |
| Range of Applications | Industrial |
| Type | Electric Holding Furnace |
| Usage | Ceramic Sintering |
| Fuel | Electric |
| Atmosphere | Vacuum/Nitrogen/Hydrogen |
| Effective Chamber Dimensions | 500*500*650mm(W*H*D) |
| Rated Temperature | 900°c |
| Maximum Temperature | 1000°c |
| Transport Package | Wooden Packaging |
| Specification | 1650*1950*2000mm(W*H*D) |
| Trademark | Chitherm |
| Origin | China |
| HS Code | 8514101000 |
| Supply Ability | 50 Sets/Year |
| Customization | Available |
| Certification | ISO |
| Place Style | Vertical |
Product Description
Chitherm Hwf160-10nh Vacuum Atmosphere Tank Furnace for Temperature Processing ISO Certified and 1000°c Maximum Temperature
1. Equipment Name and Model:
HWF160-10NH Vacuum Atmosphere Tank Furnace
2. Technical Indicators and Basic Configuration
- 2.1 Rated Temperature: 900°C;
- 2.2 Maximum Temperature: 1000°C;
- 2.3 Tank Material: SUS310S;
- 2.4 Tank Dimensions: Φ750×900mm (d×D);
- 2.5 Effective Size: 500×500×650mm (W×H×D);
- 2.6 Material Loading Method: Stainless steel saggars, a total of 7 layers, 2 saggars per layer, 14 saggars in total;
- 2.7 Cooling Method: Natural cooling;
- 2.8 Heating Element: FEC ceramic fiber heater;
- 2.9 Temperature Control Stability: ±1°C, with the function of PID parameter self-tuning;
- 2.10 Temperature Uniformity: ±5°C (tested in an empty furnace at a constant temperature of 900°C for 1 hour), with a reserved detection port;
- 2.11 Temperature Control Thermocouple: K graduation;
- 2.12 Number of Temperature Control Points: 3 points;
- 2.13 Number of Temperature Measuring Points: 1 point;
- 2.14 Number of Temperature Control Segments: Default 9 segments;
- 2.15 Sintering Atmosphere: Nitrogen, hydrogen or a mixture of nitrogen and hydrogen;
- 2.16 Oxygen Content Detection: Equipped with an oxygen content analyzer that can be used under reducing atmosphere conditions;
- 2.17 Waste Gas Treatment: The discharged hydrogen is ignited when passing through the ignition device;
- 2.18 Alarm and Protection: Sound and light alarm protection for over-temperature, thermocouple breakage, low air pressure, low water pressure, ignition, motor under-phase and reverse-phase, unqualified vacuum degree, etc., and it has the function of power-off protection for over-temperature alarm;
- 2.19 Design Power: 40kW;
- 2.20 Typical Heat Preservation Power of the Empty Furnace: ≤25kW;
- 2.21 Heating Rate: ≤5°C/min;
- 2.22 Surface Temperature Rise: <35°C;
- 2.23 Ultimate Vacuum Degree: 10Pa;
- 2.24 Equipment Weight: Approximately 1500Kg;
- 2.25 Equipment Color: Light gray;
- 2.26 Reference Dimensions of the Appearance: 1650×1950×2000mm (W×H×D), and the specific dimensions shall be subject to the actual product.
3. General Technical Description
Figure 1 Schematic Diagram of the Equipment Structure
4. Delivery List
| Item | Note | Qty. |
| Basic Components | Furnace | 1 SET |
| inspection certificate | Certificate of major outsourced components | 1 SET |
| Technical Documents | Instructions, technical documents of the major outsourced parts, etc | 1 SET |
| Key Components | Heating Element | 1 SET |
| Vacuum System | | 1 SET |
| Touch Screen | | 1 SET |
| Temperature Controller | Azbil | 1 SET |
| Thermocouple | Type K | 1 PCS |
| PLC | | 1 SET |
| Spare Parts | SSR | 1 PC |
5. Facility Requirements
- 1. Environmental Conditions: temp.: 0~40ºC, humidity ≤ 80%RH, no corrosive gas, no strong airflow disturbance.
- 2. N2 Conditions: 99.999% purity, working pressure: 0.2-0.4MPa, Max gas consumption 2-6 m3/h.
- 3. H2 Conditions: working pressure: 0.2-0.4MPa, Max gas consumption 1-3m3/h.
- 4. Water Conditions: clean, no corrosive water, working pressure 0.1-0.3MPa, 3-9L/min
- 5. Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 15m3/h
- 6. Ground Requirements: horizontal, no obvious vibration, load-bearing> 500 kg/m2;
- 7. Power Condition(TBD): capacity > 55kVA, 3-phases 5-lines, voltage 220/380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
- 8. Installation Site: 3000mm×2500mm×3000mm(D×W×H), with an installation area greater than 7.5m2.