Product Description
Chitherm Hpf190-03n Vacuum Dryer Electric Holding Furnace 755mm*1680mm*950mm W*H*D for Versatile Drying Applications
1. Typical Applications
Primarily used for drying, debinding, and curing of electronic components in vacuum or controlled atmosphere environments.
2. Parameter Characteristics
- 2.1 Operating Temperature: RT~200°C
- 2.2 Maximum Temperature: 250°C
- 2.3 Furnace Chamber Material: SUS304 stainless steel
- 2.4 Insulation Material: Ceramic fiber
- 2.5 Chamber Dimensions: 500mm*700mm*550mm (W*H*D)
- 2.6 Temperature Uniformity: Surface temperature uniformity of heating plates: within ±5°C (tested at 200°C constant temperature)
- 2.7 Heating Elements: Aluminum heating plates
- 2.8 Number of Heating Plates: 4
- 2.9 Maximum Heating Power: 4*1.5kW
- 2.10 Heating Rate: ≤5°C/min
- 2.11 Temperature Control Element: Platinum resistance (PT100)
- 2.12 Temperature Control Points: 4 points
- 2.13 Temperature Control Method: Cycle zero-crossing control
- 2.14 Centralized Control: Touch screen + PLC centralized control
- 2.15 Temperature Control Accuracy: ±1°C
- 2.16 Ultimate Vacuum: ≤50Pa
- 2.17 Vacuum Pumping Time: ≤30 minutes (from atmospheric pressure to 0.1mbar)
- 2.18 Chamber Pressure Resistance: 0.1~1mbar (operable under vacuum or atmospheric pressure)
- 2.19 Vacuum Alarm: Triggers an alarm and shuts off the vacuum pump if the preset vacuum level is not achieved within the specified time
- 2.20 Alarm Protections: Audible/visual alarms for over-temperature, motor overload, and phase reversal failure
- 2.21 Noise Level: ≤63dB
- 2.22 Exterior Finish: High-temperature spray coating, light gray
- 2.23 Overall Dimensions (Reference): 755mm*1680mm*950mm (W*H*D)
3. Delivery Checklist
| Category | Name | Main Contents | Quantity |
| Basic Components | Furnace Main Unit | | 1 unit |
| Inspection Certificates | Certificates for key purchased components | | 1 set |
| Technical Documents | User manual | Technical documents for key purchased components, etc. | 1 set |
| Key Components | Heating Plates | | 4 pieces |
| Touch Screen | | 1 unit |
| Resistive Vacuum Gauge | | 1 unit |
| Resistive Gauge Tube | | 1 unit |
| Spare Parts | Solid-State Relay (SSR) | | 1 piece |
4. Equipment Normal Operating Conditions
- 4.1 Environmental Conditions: Temperature 0~40°C, humidity ≤80% RH, no corrosive gases, no strong airflow disturbances
- 4.2 Gas Supply Requirements:
- High-purity nitrogen (process protective gas): Purity >99.999%, inlet pressure 0.1~0.2MPa
- Dry, clean, oil-free compressed air (purge gas): Inlet pressure 0.4~0.8MPa
- 4.3 Ventilation System: Non-contact connection to user's exhaust system, exhaust capacity >10m³/h
- 4.4 Floor Requirements: Level surface, minimal vibration, load-bearing capacity >200kg/m²
- 4.5 Power Supply: Capacity >8kVA, three-phase five-wire system, AC380V, 50Hz
- 4.6 Installation Space: 2000mm*2000mm*3000mm (Depth*Width*Height), installation area >4m²