Schneider standards 140DDO84300 7.5 A for 50 s Tsx Quantum Output Module 10-60v-dc
  
   
Factory installed fuse pullers are standard on 30–100 A, NEMA Type 4/4X/5 stainless steel, NEMA Type 4X fiberglass reinforced polyester and
 NEMA Type 12 or 12K switches; Available as a kit for field installation on 30–100 A, F Series switches, NEMA Type 1 and 3R switches
 • 30–600 A switches are shipped with standard Class H fuse spacing. These switches will accept Class R fuses also; A field-installed rejection
 kit is available, which when installed, rejects all but Class R fuses; See page 32 for Class R Fuse Kits
 • Fuse load base(s) can be repositioned to accept Class J fuses on 30–600 A, 600 V switches and 100–600 A, 240 V switches;
 600 A switches also require a mounting kit (catalog number H600J)
 • Multiple padlock provision in OFF position (three 3/16-5/16 in. (4-7 mm) shank padlocks)
 • Provisions to lock ON with one 3/8 in. (9 mm) padlock available factory installed, except for NEMA Type 7/9 and NEMA Type 4X fiberglass
 reinforced polyester switches
 • Tangential knockouts, where provided, lessen the need for conduit offset bends
 • Lock-OFF provision is standard on all heavy duty safety switches
140CPU11302
140CPU11303
140CPU31110
140CPU43412A
140CPU43412U
140CPU53414B
140CPU65150
140CPU67160
TCSESM043F2CU0
TCSESM083F2CU0
TCSESM083F2CS0
TCSESM163F2CU0
TCSESM243F2CU0
140DDM39000
140CRA21110
140DAO84210
140DRC83000
TSXDEY16D2
140XBP00600
140NOE77101
140CRA93200
140CRP93200
140ACI03000
140ACO02000
140DDI35300
140DAI74000
140DDO35300
TCSESM083F2CUO
140ARI03010
140CPS21400
975750000
140CPU65260C
140CPS11420C
140DDI35300C
140DDO35300C
140ACI04000C
OTHER SUPERIOR PRODUCTS
| Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- | 
| Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- | 
| Honeywell TC-,TK- | GE Modules IC - | 
| Fanuc motor A0- | Yokogawa transmitter EJA- | 


response time
 <= 1 ms at state 0 to state 1
 <= 1 ms at state 1 to state 0
 maximum leakage current
 1 mA 60 V
 load inductance
 Inductance(H) = 0.5/((current(A))² x (switching frequency(Hz)))
 associated fuse rating
 2 A each point
 8 A per group
 isolation between channels and bus
 2500 Vrms DC for 1 minute
 isolation between group
 700 Vrms DC for 1 minute
 protection type
 Internal output protection by 8 A fuse per group
 power dissipation
 1 W + (1 V x total module load current)
 marking
 CE
 local signalling
 1 LED (green)bus communication is present (Active):
 1 LED (red)external fault detected (F):
 16 LEDs (green)input status:
 bus current requirement
 160 mA
 module format
 Standard
 net weight
 0.45 kg
 Environment
 product certifications
 GOST
 RMRS
 FM Class 1 Division 2
 C-Tick
 standards
 CSA C22.2 No 142
 UL 508
 resistance to electrostatic discharge
 4 kV contact conforming to IEC 801-2
 8 kV on air conforming to IEC 801-2
 resistance to electromagnetic fields
 10 V/m 80…2000 MHz conforming to IEC 801-3
 ambient air temperature for operation
 0…60 °C
 ambient air temperature for storage
 -40…85 °C
 relative humidity
 95 % without condensation
 operating altitude
 <= 5000 m
 Offer Sustainability
 Sustainable offer status
 Green Premium product
 REACh Regulation
 REACh Declaration
 EU RoHS Directive
 Pro-active compliance (Product out of EU RoHS legal scope)
 EU RoHS Declaration
 Mercury free
 Yes
 RoHS exemption information
 Yes
 China RoHS Regulation
 China RoHS declaration
 Environmental Disclosure
 Product Environmental Profile
 Circularity Profile
 End of Life Information
 WEEE
 The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins