HT Sensor DIN Mounting Differential Pressure Transmitter for Gas and Liquid Measurement
BP93420DII Differential Pressure Transmitter
Introduction of differential pressure transmitter:
BP93420DII differential pressure transmitter uses diffused silicon piezoresistive sensor.When the pressure difference of the measured medium is located on the corrugated diaphragm on both sides of the sensor, the signal output by the Wheatstone bridge of the sensor chip has a good linear relationship with the pressure difference, and the pressure difference can be accurately measured.It is suitable for pressure difference measurement of various gases and liquids in pipelines of petroleum, chemical, electric power, hydrology and other industries.
Product Features of differential pressure transmitter:
Performance Parameters of differential pressure transmitter: | |
---|---|
Measurement Range | 0-10KPa……~2MPa |
Pressure Type | Differential Pressure |
Single-side Overload | ≤3 times of the rated range |
Static pressure | The minimum value between 5 times the rated range or 7 MPa |
Accuracy @ 25℃ | ±0.25% (Typical) ±0.5% (Maximum) |
Repeatability | ±0.03% (Typ.) ±0.05%FS (Max.) |
Hysteresis | ±0.03% (Typ.) ±0.05%FS (Max.) |
Long-Term Stability | ±0.5%F.S/Year(≤200KPa) ±0.2%F.S/Year(>200KPa) |
Zero Temperature Drift | ±0.01%FS/℃(>100KPa), ±0.02%FS/℃ (≤100Kpa) |
Span Temperature Drift | ±0.01%FS/℃(>100KPa), ±0.02%FS/℃ (≤100Kpa) |
Compensation Temperature | 0-50℃(0-10KPa, 0-20KPa) ,0-70℃ ,-10-70℃ |
Operating Temperature | -30℃~80℃ |
Storage Temperature | -40℃~100℃ |
Vibration | 10g,55Hz ~ 2kHz |
Housing Material | 304,316L |
Diaphragm Material | 316L |
Insulation Resistance | 100MΩ 100VDC |
Explosion-proof Rating | Intrinsically safe and explosion-proof |
Protection Rating | IP65 |
Weight | ~0.45kg |
Output Signal | Supply Voltage | Output Type |
---|---|---|
4~20mA | 12~30VDC | 2/3/4 wire |
0~10/20mA |
3 wire | |
0/1~5V | ||
0.5~4.5V | 5VDC |
Order Guide of differential pressure transmitter: | ||||||||
BP93420XX | Pressure Transmitter | |||||||
Code | Outline Construction | |||||||
DII | Differential Pressure Transmitter | |||||||
Measurement Range | 0-10KPa……~2MPa | |||||||
Code | Power Supply | |||||||
D1 | 24VDC | |||||||
D2 | 5VDC | |||||||
D3 | Other | |||||||
Code | Output Signal | |||||||
S1 | 4~20mADC | S5 | 0~20mADC | |||||
S2 | 1~5VDC | S6 | 0~10VDC | |||||
S3 | 0~5VDC | S7 | 0.5~4.5VDC | |||||
S4 | 0~10mADC | |||||||
Code | Pressure Connection | |||||||
J1 | M20×1.5 Male | |||||||
J2 | G1/2 Male | |||||||
J3 | G1/4 Male | |||||||
J4 | 1/2 NPT Male | |||||||
J5 | Other | |||||||
Code | Electrical Connection | |||||||
B1 | Hirschmann | |||||||
B2 | PG7 Plug | |||||||
B3 | Sealed Cable Output | |||||||
B4 | Other | |||||||
Code | Pressure Type | |||||||
D | Differential Pressure |