Model: LNK-IPMU-HS19-1U-CR1.8-Q1-G10A8-FMTX
Overview
Features
► 100–240V AC input, 8 total outlets
► Max 16A / 2800W Output
► Support 19 inch Rack-mount
► Gen 3 Replaceable Surge Protection module
► L and N Double-break Switch
► UL94V-0 Grade Flame Resistant Material
► Four-layer Piano Paint T6 Hardened Aluminum Profile
► Complies with the requirements of IEC60297 standards
► EMI.RFI Protection
Technical Indexes
OUTPUT | |
PDU type | 19 inch rack mount Surge Protection PDU |
Voltage output | 85V~265VAC |
Working Frequency | 50/60Hz |
Output Capacity Details | 3.68kW (230V), 1.76kW(110V) |
Outlets type | US, EU, UK, IEC available |
Overload Protection | Yes |
Voltage Measurement | Range: 0~300V |
Display Digits: 0.01V | |
Current Measurement | Input: Transformer |
Range: 0~30mA | |
Display Digits: 0.01A | |
Power Measurement | Accuracy: Grade 1 |
Display Digits: 0.01kW | |
Electricity Measurement | Accuracy: Grade 1 |
Display Digits: 0.01kW | |
Display | OLED Screen, Blue text on black / White text on black |
INPUT | |
PDU Input Voltage | 100-240V AC |
Maximum Input Amps | 10/16A |
PDU Plug Type | US, EU, UK, IEC 3 Pin available |
Phase line | Single Phase |
Input Cord Details | 1.8m / 5.9ft |
PHYSICAL | |
Form Factors Supported | 1U rackmount, 0U vertical rackmount, wall-mount, and under-counter installation |
Material of Construction | Aluminum T6 Hardened Profile with Four-layer Piano Paint |
Minimum Required Rack Depth | 59mm / 2.3in |
Unit Weight | 1.05kg / 2.31 lbs |
Photosensitive Detection | Normally used for automatic lighting with extended functions |
ENVIRONMENTAL | |
Operating Temperature | -10 to 50°C |
Storage Temperature | -30 to 60°C |
Relative Humidity | 5 to 95% non-condensing |
Operating Elevation | 0-4000m |
Warranty Period | 5-year limited warranty |
ordering information
Model Number | Installation | specification | Input Cable | Input | Output | Output Interface | accessories | Remark | |
Control | |||||||||
LNK-IPMU-HS19-1U-CR1.8-Q1-G10A8-FMTX | Horizontal | 19’’ | 1U | 1.8m | 85-265VAC | GB2015, Max=13A, 8CH Control output | GB1002(10A/250V) | Smart Meter | Input Plug Customizable |
LNK- IPMU-HS19-1U-CR1.8-Q1-C13A7-FMTX |
Horizontal | 19’’ | 1U | 1.8m | 85-265VAC | IEC320-C1 (Cable anti falling), Max=13A, 7CH Control output | IEC60320 C13 | Smart Meter | Input Plug Customizable |
LNK-IPMU_HS19_1U_CR1.8_Q1_Y16A7_FMTX |
Horizontal | 19’’ | 1U | 1.8m | 85-265VAC | Universal plug Max=16A, 7CH Control output | GB 2099.3(16A/250V) | Smart Meter | Input Plug Customizable |
LNK-IPMU_HS19_1U_CR1.8_Q1_Y16A8_FMTX |
Horizontal | 19’’ | 1U | 1.8m | 85-265VAC | Universal plug Max=16A, 8CH Control output | NEMA5-15R(16A/250V) | Smart Meter | Input Plug Customizable |
Application