Number of channels :
One
Hazardous-area input :
Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
Safe-area output :
Single pole relay with changeover contacts Note: reactive loads must be adequately suppressed
Maximum current consumption :
25mA at 24V
Power dissipation within unit :
0.6W at 24V
LED indicator :
Green: power indication Yellow: channel status, on when output energised Red: LFD indication, on when line fault detected
Description

MTL5511 SWITCH/ PROXIMITY DETECTOR INTERFACE

The MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the line- fault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for the channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.

SPECIFICATION

Location of switches

Zone 0, IIC, T6 hazardous area

Div. 1, Group A hazardous location

Location of proximity detector

Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location

Hazardous-area inputs

Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)

Voltage applied to sensor

7 to 9V dc from 1kΩ ±10%

Input/output characteristics

Normal phase

Outputs closed if input > 2.1mA (< 2kΩ in input circuit) Outputs open if input < 1.2mA (> 10kΩ in input circuit)

Hysteresis: 200µA (650Ω) nominal

Line fault detection (LFD) (when selected)

User-selectable via switches on the side of the unit. A line fault is indicated by an LED. The channel output relay is de-energisedif an input line fault is detected.

Open-circuit alarm on if Iin < 50µA

Open-circuit alarm offif Iin > 250µA

Short-circuit alarm on if Rin < 100Ω

Note: Resistors must be fitted when using the LFD facility with a contact input 500Ω to 1kΩ in series with switch 20kΩ to 25kΩ in parallel with switch

Safe-area output

Single pole relay with changeover contacts

Note: reactive loads must be adequately suppressed

LED indicators

Green: power indication

Yellow: channel status, on when output energised

Red: LFD indication, on when line fault detected

Maximum current consumption

25mA at 24V

Power dissipation within unit

0.6W at 24V

Related Part Number:

HCU16 MTL5521 MTL4546Y MTL7761PAC
HCU3700 MTL5522 MTL4549Y MTL7765AC
HM64RIB20-1.0 MTL5531 MTL4573 MTL7787+
HM64RIB20-1.5 MTL5532 MTL4575 MTL7787P+
HMM64 MTL5541 MTL4646Y MTLCPS16
HMRIB16-1.0 MTL5541S MTL4850 NJ5-18GK-N
HMS64 MTL5544 MTL4851 SD150X
HTP-SC32 MTL5544D MTL4852 SD32
MTL4044D MTL5546 MTL5018 SD32X
MTL4511 MTL5546Y MTL5032 SDRTD
MTL4516 MTL5561 MTL5042 SLP32D
MTL4516C MTL5573 MTL5044 TP48-3-I-NDI
MTL4521 MTL5575 MTL5049 TP48-3-N-NDI
MTL4541 MTL5582B MTL5511 TP48-4-I-NDI
PCL45USB MTL7728+ MTL5514D TP48-4-N-NDI
MTL4544 MTL7756AC MTL5516 TP48-N-NDI
MTL4544D MTL7760AC MTL5516C ZB24571

MTL5511 Switch Proximity Detector Interface 25mA 24V

Send your message to this supplier
Send Now

MTL5511 Switch Proximity Detector Interface 25mA 24V

Ask Latest Price
Brand Name :
MTL
Model Number :
MTL5511
Certification :
CE
Place of Origin :
USA
MOQ :
1 piece
Price :
negotiable
Contact Supplier
MTL5511 Switch Proximity Detector Interface 25mA 24V
MTL5511 Switch Proximity Detector Interface 25mA 24V
MTL5511 Switch Proximity Detector Interface 25mA 24V
MTL5511 Switch Proximity Detector Interface 25mA 24V
MTL5511 Switch Proximity Detector Interface 25mA 24V
MTL5511 Switch Proximity Detector Interface 25mA 24V

SC Automation Limited

Verified Supplier
2 Years
hong kong
Since 2010
Business Type :
Trading Company
Total Annual :
5000000-8000000
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement