PMP75-AAG1H2EAF13E+PASA PMP75-AAG1PEEAF13E+PASA PMP75-AAG1PEEB313E+PASA
Product Highlights
- Large variety of different process connections and membrane materials
- New TempC Membrane minimizes influences of ambient and process temperature fluctuations
- HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
- Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
- Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
- Cost savings with modular concept for easy replacement of sensor, display or electronics
- Overload-resistant and function-monitored from the measuring cell to the electronics<
Field of Application
Single chamber aluminum or stainless steel (316L) housing.
- Process connections: Threads, flanges or hygienic connections
- Process temperature: -70 to +400°C (-94 to +752°F)
- Pressure: -1/0 up to 400bar (-15/0 up to +6,000psi)
- Accuracy: ±0.075%
- International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals
item
|
value
|
Grade
|
Industrial
|
Customized support
|
ODM
|
Place of Origin
|
China
|
Brand Name
|
Endress+Hauser
|
Model Number
|
PMP75-AAA1SB11GAAA+L8
|
MOQ
|
1pcs
|
Brand Name
|
E+H
|
Delivery time
|
1-3 days
|
Pressure measurement range
|
100mbar...400bar (1.5...5800 psi)
|
Maximum measurement distance
|
7000m (22.966ft) H2O
|
Anti vacuum pressure
|
10 mbar (1.45 psi)
|
Maximum overvoltage limit
|
1050bar (15.750psi)
|
Alternative products
|
PMP71B
|