Overview: Gammapilot FMG50
The Gammapilot FMG50 is a versatile, non-contact radiometric instrument designed for measuring level (continuous and point), interface, density, and concentration across liquids, solids, suspensions, and sludges
Key Applications
- Continuous level and point-level detection
- Interface measurement between different media (e.g., liquid/liquid or liquid/solid)
- Density and concentration measurement using gamma beam attenuation
What Makes It Stand Out
- Uses radiometric (gamma-ray) measurement, meaning it works through vessel walls and in highly challenging environments—corrosive, viscous, toxic, high-temperature or high-pressure
- The first true 2-wire loop-powered compact transmitter, reducing wiring complexity and installation costs
- Compact size with scintillator detectors such as NaI(Tl) or PVT, available in various lengths to fit measurement needs
Performance & Safety Features
Accuracy & Range
- Provides high accuracy (~±1%) and essentially unlimited measuring range, and can operate in cascade configurations for extended distances
Functional Safety & Diagnostics
- Certified to SIL 2/3 under IEC 61508, offering high functional safety for critical applications
- Heartbeat Technology enables in-process diagnostics and verification without disrupting measurements
Wireless Operation
- Equipped with Bluetooth® connectivity, allowing commissioning, configuration, and diagnostics via the SmartBlue app, ideal for hard-to-access measurement points
High-Temperature Operation
- Designed with advanced sensor materials and low internal heat generation, enabling operation up to +80 °C ambient without water cooling
Radiation Efficiency
- Features a highly sensitive scintillator detector that demands around 80% lower radiation dose compared to older detectors (e.g., Geiger-Mueller), improving safety and efficiency.
Technical Highlights
Feature
|
Details
|
Measurement Modes
|
Continuous level, point level, interface, density, concentration
|
Process Compatibility
|
Liquids, solids, suspensions, sludges
|
Environment Suitability
|
High pressure, high temperature, corrosive or toxic media
|
Power & Communication
|
2-wire loop-powered, 4–20 mA HART
|
Safety & Certification
|
SIL2/3, ATEX, IECEx, and other global certifications
|
Diagnostic Tools
|
Heartbeat Technology, Bluetooth via SmartBlue
|
Accuracy
|
±1%
|
Ambient Operation Range
|
–40 °C to +80 °C
|
Sensor Options
|
NaI(Tl), PVT scintillators (varied lengths)
|
Radiation Source
|
Uses gamma isotopes like Cs-137 or Co-60, via source containers
|
How It Measures—Simplified
- A gamma radiation source sits opposite the FMG50 detector.
- The medium between them attenuates the gamma rays.
- Level detection: A full path (filled) vs. empty path determines level presence
- Density: Denser medium absorbs more radiation, yielding lower detector signal—used to calculate density and even mass flow (when combined with a flow device)
- Interface profiling: Changes in density help locate the boundary between layers
Summary of Benefits
- Simplified installation: Single loop wiring and wireless setup thanks to Bluetooth.
- Robust measurement: Non-invasive through vessel walls—ideal for extreme or hazardous conditions.
- High safety standards: SIL-certified with advanced diagnostics and lower radiation exposure.
- Flexible configuration: Supports multiple measurement modes with adaptable detection technology.