Specifications
Secondary Winding :
2
Isolation Voltage(Vrms) :
4kV
Primary Winding(s) :
2
Secondary Side Voltage :
14V;28V
Output Current :
9.2A;4.6A
Primary Side Voltage :
115V;230V
Description :
Screw Terminals Power Transformers RoHS
Mfr. Part # :
A41-130-28
Model Number :
A41-130-28
Package :
Screw Terminals
Description

Product Overview

The Belfuse A41 Series All-4-One International Transformers are designed to provide high isolation, creepage, and clearance necessary to comply with international safety standards. These transformers offer international standards at a lower cost with improved performance. They are suitable for chassis mounting and are RoHS Compliant.

Product Attributes

  • Brand: Belfuse (Signal Transformer)
  • Series: A41 Series All-4-One
  • Insulation Class: Class F (155 C)
  • Flammability Rating: Bobbin and shroud material meet UL 94-V0
  • Certifications: UL 1446 (File # E66312), UL recognized to UL 506 / UL 5085-2 (File # E63829), CSA certified to C22.2 No 66.1 (File # 221070), VDE certified to VDE 0868 / EN 62368 (File # 1448), CE Compliance, VDE Declaration of Conformity LVD 2014/35/EU, RoHS Compliant
  • Custom versions available upon request.

Technical Specifications

Part Number VA Secondary RMS Rating (Series) Secondary RMS Rating (Parallel) Size Mounting Style Mounting Screw Weight (lbs/kg)
A41-25-10 25 10.0 VCT @ 2.5 A 5.0 V @ 5.0 A 25 C #6 1.25 (0.57)
A41-43-10 43 10.0 VCT @ 4.3 A 5.0 V @ 8.6 A 43 C #6 1.6 (0.73)
A41-80-10 80 10.0 VCT @ 8.0 A 5.0 V @ 16.0 A 80 B #6 2.8 (1.27)
A41-130-10 130 10.0 VCT @ 13.0 A 5.0 V @ 26.0 A 130 B #8 4.1 (1.86)
A41-175-10 175 10.0 VCT @ 17.5 A 5.0 V @ 35.0 A 175 B #8 5.5 (2.49)
A41-25-12 25 12.6 VCT @ 2.0 A 6.3 V @ 4.0 A 25 C #6 1.25 (0.57)
A41-43-12 43 12.6 VCT @ 3.4 A 6.3 V @ 6.8 A 43 C #6 1.6 (0.73)
A41-80-12 80 12.6 VCT @ 6.3 A 6.3 V @ 12.6 A 80 B #6 2.8 (1.27)
A41-130-12 130 12.6 VCT @ 10.3 A 6.3 V @ 20.6 A 130 B #8 4.1 (1.86)
A41-175-12 175 12.6 VCT @ 14.0 A 6.3 V @ 28.0 A 175 B #8 5.5 (2.49)
A41-25-16 25 16.0 VCT @ 1.6 A 8.0 V @ 3.2 A 25 C #6 1.25 (0.57)
A41-43-16 43 16.0 VCT @ 2.7 A 8.0 V @ 5.4 A 43 C #6 1.6 (0.73)
A41-80-16 80 16.0 VCT @ 5.0 A 8.0 V @ 10.0 A 80 B #6 2.8 (1.27)
A41-130-16 130 16.0 VCT @ 8.1 A 8.0 V @ 16.2 A 130 B #8 4.1 (1.86)
A41-175-16 175 16.0 VCT @ 11.0 A 8.0 V @ 22.0 A 175 B #8 5.5 (2.49)
A41-25-20 25 20.0 VCT @ 1.25 A 10 V @ 2.5 A 25 C #6 1.25 (0.57)
A41-43-20 43 20.0 VCT @ 2.2 A 10 V @ 4.4 A 43 C #6 1.6 (0.73)
A41-80-20 80 20.0 VCT @ 4.0 A 10 V @ 8.0 A 80 B #6 2.8 (1.27)
A41-130-20 130 20.0 VCT @ 6.5A 10 V @ 13.0 A 130 B #8 4.1 (1.86)
A41-175-20 175 20.0 VCT @ 8.8A 10 V @ 17.6 A 175 B #8 5.5 (2.49)
A41-25-24 25 24.0 VCT @ 1.0 A 12.0 V @ 2.0 A 25 C #6 1.25 (0.57)
A41-43-24 43 24.0 VCT @ 1.8 A 12.0 V @ 3.6 A 43 C #6 1.6 (0.73)
A41-80-24 80 24.0 VCT @ 3.3 A 12.0 V @ 6.6 A 80 B #6 2.8 (1.27)
A41-130-24 130 24.0 VCT @ 5.4 A 12.0 V @ 10.8 A 130 B #8 4.1 (1.86)
A41-175-24 175 24.0 VCT @ 7.3 A 12.0 V @ 14.6 A 175 B #8 5.5 (2.49)
A41-25-28 25 28.0 VCT @ 0.9 A 14.0 V @ 1.86 A 25 C #6 1.25 (0.57)
A41-43-28 43 28.0 VCT @ 1.5 A 14.0 V @ 3.0 A 43 C #6 1.6 (0.73)
A41-80-28 80 28.0 VCT @ 2.8 A 14.0 V @ 5.6 A 80 B #6 2.8 (1.27)
A41-130-28 130 28.0 VCT @ 4.6 A 14.0 V @ 9.2 A 130 B #8 4.1 (1.86)
A41-175-28 175 28.0 VCT @ 6.25 A 14.0 V @ 12.5 A 175 B #8 5.5 (2.49)
A41-25-36 25 36.0 VCT @ 0.7 A 18.0 V @ 1.4 A 25 C #6 1.25 (0.57)
A41-43-36 43 36.0 VCT @ 1.2 A 18.0 V @ 2.4 A 43 C #6 1.6 (0.73)
A41-80-36 80 36.0 VCT @ 2.2 A 18.0 V @ 4.4 A 80 B #6 2.8 (1.27)
A41-130-36 130 36.0 VCT @ 3.6 A 18.0 V @ 7.2 A 130 B #8 4.1 (1.86)
A41-175-36 175 36.0 VCT @ 4.8 A 18.0 V @ 9.6 A 175 B #8 5.5 (2.49)
A41-25-230 25 230 VCT @ 0.11 A 115 V @ 0.22 A 25 C #6 1.25 (0.57)
A41-43-230 43 230 VCT @ 0.19 A 115 V @ 0.38 A 43 C #6 1.6 (0.73)
A41-80-230 80 230 VCT @ 0.35 A 115 V @ 0.7 A 80 B #6 2.8 (1.27)
A41-130-230 130 230 VCT @ 0.57 A 115 V @ 1.14 A 130 B #8 4.1 (1.86)
A41-175-230 175 230 VCT @ 0.76 A 115 V @ 1.52 A 175 B #8 5.5 (2.49)
VA L (inches/mm) W (inches/mm) H (inches/mm) A (inches/mm) B (inches/mm) C (inches/mm) Terminal Size (inches/mm) Mounting Dimension (inches/mm)
25 2.81 (71.4) 2.14 (54.4) 2.31 (58.7) 2.00 (50.8) 1.12 (28.6) .31 (7.9) .187 (4.75) 2.37 (60.3)
43 3.12 (79.4) 2.14 (54.4) 2.68 (68.2) 2.25 (57.2) 1.12 (28.6) .31 (7.9) .187 (4.75) 2.81 (71.4)
80 2.50 (63.5) 2.52 (64.3) 3.06 (77.7) 1.37 (35.0) .31 (7.9) .187 (4.75) 2.00 (50.8)
130 2.81 (71.4) 3.00 (76.2) 3.37 (85.7) 1.62 (41.3) .37 (9.5) 0.25 (6.35) 2.25 (57.2)
175 3.12 (79.4) 3.14 (79.7) 3.75 (95.3) 1.62 (41.3) .37 (9.5) 0.25 (6.35) 2.50 (63.5)

General Specifications:

  • Power: 25 VA to 175 VA
  • Dielectric Strength: 4000 Vrms Hipot
  • Primaries: Dual primaries (115/230 V - 50/60 Hz)
  • Dual Secondaries: Series or parallel
  • Terminals: Solder lug / quick connect type terminals
  • Leakage Current: Meets UL 60601-1, IEC/EN 60601-1

2411272144_Bel-Fuse-A41-130-28_C17370916.pdf

Send your message to this supplier
Send Now

High Isolation Industrial Transformer Bel Fuse A41-130-28 With Multiple International Certifications

Ask Latest Price
Secondary Winding :
2
Isolation Voltage(Vrms) :
4kV
Primary Winding(s) :
2
Secondary Side Voltage :
14V;28V
Output Current :
9.2A;4.6A
Primary Side Voltage :
115V;230V
Contact Supplier
High Isolation Industrial Transformer Bel Fuse A41-130-28 With Multiple International Certifications

Changsha Purple Horn E-Commerce Co., Ltd.

Verified Supplier
1 Years
hunan, changsha
Since 2009
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer
Employee Number :
>300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement