E4 Portable NIBP Vitals Monitor Multi Parameter Patient Monitor For Hospital Bedside
|  			 Quality Standards and Classification  			 |  			 			 CE, ISO13485  			 |  		
|  			 SFDA: ClassⅡb  			 |  		|
|  			 Anti-electroshock degree:  			 |  		|
|  			 ClassⅠequipment  			 |  		|
|  			 (internal power supply)  			 |  		|
|  			 CO2/SpO2 /NIBP: BF  			 |  		|
|  			 Display  			 |  			 			 4” real color TFT screen  			 |  		
|  			 Resolution: 480*800  			 |  		|
|  			 One alarm indicator(yellow/red)  			 |  		|
|  			 Standard touch screen  			 |  		|
|  			 Environment  			 |  			 			 Operating environment :  			 |  		
|  			 Temperature: 0 ~ 40℃  			 |  		|
|  			 Humidity: ≤85%  			 |  		|
|  			 Altitude: -500 ~ 4600m  			 |  		|
|  			 Transport and Storage environment :  			 |  		|
|  			 Temperature: -20 ~ 60℃  			 |  		|
|  			 Humidity: ≤93%  			 |  		|
|  			 Altitude: -500 ~ 13100m  			 |  		|
|  			 Power Requirements  			 |  			 			 AC: 100 ~ 240V, 50Hz/60Hz  			 |  		
|  			 DC: Built-in rechargeable battery  			 |  		|
|  			 Battery: 3.7V 2000mAh  			 |  		|
|  			 Fully charged for about 5 hours (single blood oxygen)  			 |  		|
|  			 5min operating after low battery alarm  			 |  		|
|  			 Dimension and Weight  			 |  			 			 Host size: 155*72.5*28.6mm 773g(about)  			 |  		
|  			 Package: 217*213*96mm  			 |  		|
|  			 Storage  			 |  			 			 Can store 500~1000 sets of historical data  			 |  		
|  			 NIBP  			 |  			 			 Method: Pulse wave oscillometry  			 |  		
|  			 Work mode: Manual/ Auto/ STAT  			 |  		|
|  			 Measure interval of auto mode:  			 |  		|
|  			 1,2,3,4,5,10,15,30,60,90,120  			 |  		|
|  			 Measuring Time of STAT Mode: 5 minutes  			 |  		|
|  			 PR range: 40 ~ 240bpm  			 |  		|
|  			 Measure & alarm range:  			 |  		|
|  			 Adult  			 |  		|
|  			 SYS 40 ~ 270mmHg  			 |  		|
|  			 DIA 10 ~ 215mmHg  			 |  		|
|  			 MEAN 20 ~ 235mmHg  			 |  		|
|  			 Pediatric  			 |  		|
|  			 SYS 40 ~ 200mmHg  			 |  		|
|  			 DIA 10 ~ 150mmHg  			 |  		|
|  			 MEAN 20 ~ 165mmHg  			 |  		|
|  			 Static pressure range: 0 ~ 300mmHg  			 |  		|
|  			 Pressure precision:  			 |  		|
|  			 Max. average error: ±5mmHg  			 |  		|
|  			 Max. standard deviation: ±8mmHg  			 |  		|
|  			 Overvoltage protection:  			 |  		|
|  			 Adult 300mmHg  			 |  		|
|  			 Pediatric 240mmHg  			 |  		|
|  			 Pulse Rate  			 |  			 			 Range: 30 ~ 240bpm  			 |  		
|  			 Resolution: 1bpm  			 |  		|
|  			 Precision: ±3bpm  			 |  		|
|  			 SPO2  			 |  			 			 Range: 0 ~ 100%  			 |  		
|  			 Resolution: 1%  			 |  		|
|  			 Precision:  			 |  		|
|  			 80% ~ 100%: ±2 %  			 |  		|
|  			 70% ~ 80%: ±3 %  			 |  		|
|  			 0% ~ 69%: ±no definition given  			 |  		|
|  			 CO2  			 |  			 			 Only side stream  			 |  		
|  			 Warm-up time:  			 |  		|
|  			 when the ambient temperature is 25 ℃, the carbon dioxide curve (capnogram) can be displayed within 20/15 seconds, and all the  			 |  		|
|  			 specifications can be fulfilled within 2 minutes.  			 |  		|
|  			 Measurement range:  			 |  		|
|  			 0-150mmHg, 0-19.7%,0-20kPa (at 760mmHg),  			 |  		|
|  			 atmospheric pressure provided by the host.  			 |  		|
|  			 Resolution  			 |  		|
|  			 0.1mmHg : 0-69mmHg  			 |  		|
|  			 0.25mmHg : 70-150mmHg  			 |  		|
|  			 Precision  			 |  		|
|  			 0-40mmHg : ±2mmHg  			 |  		|
|  			 41-70mmHg : ±5%(reading)  			 |  		|
|  			 71-100mmHg : ±8%(reading)  			 |  		|
|  			 101-150mmHg :±10%(reading)  			 |  		|
|  			 Respiratory rate range 0- 150 BPM  			 |  		|
|  			 Respiratory rate accuracy: ±1 BPM  			 |  		|
|  			 Application Range  			 |  			 			 Adult/Pediatric/Neonatal/Medicine/Surgery/Operating Room/ICU/CCU/Transfer  			 |  		