Pharmaceutical Stability Test Chamber for Stability Testing RDS-250T Applications
- Electronic PID control programmed multi-stage setting;
- Intelligent operating system, high-performance processor simple and user-friendly operation; adopts 7-inch LCD touch screen with an easy-to-understand menu operation guide.
- Data recording and storage function, capable of storing experimental data for three years (recording once per minute). The original data can be exported via a USB flash drive and cannot be modified.
- Historical temperature and humidity data or real-time curves (within the last 8 to 10 hours) can be viewed.
- Audit trail and data traceability function: It can store 16,000 operation and alarm logs, and the data is stored in the system and exported via a USB flash drive, which cannot be modified.
- Permission management: Administrators can create five users and assign different permissions.
- It has a multi-point temperature correction function to avoid linear mismatch of multi-point temperatures.
- Adopting brand compressors and condensing fans, and environmentally friendly refrigerants;
- Variable frequency refrigeration system, energy saving, small temperature and humidity fluctuations, and quick door opening recovery.
- Capacitive humidity sensor, accurate and reliable, requires no maintenance.
- The right side of the box is standard-equipped with a test hole with a diameter of 50mm.
- The double-door structure design features tempered glass on the inner door, allowing for direct observation of the test conditions inside the working chamber.
- The box is reserved with standard communication interfaces such as USB, RS485 and RS232, which can be integrated into the LIMS system.
- Menu switching function between Chinese and English.
| Model |
RD5-150T |
RDS-250T |
RD5-450T |
| Control mode |
P+-D fuzzy logic control, ordinary/program fuzzy operation |
| Display screen |
7-inch LCD touch screen |
| Temperature range |
No light -10ºC-85ºC There is light. 5ºC-65ºC |
| Humidity range |
No light 15-95%RH/±2%RH There is light 20-95%RH±2%RH |
| Temperature control accuracy |
±0.1ºC |
| Humidity fluctuation degree |
±2%RH |
| Light intensity |
6000LUX |
| Illuminance deviation |
≤500LUX |
| External dimensions (W*H*D) mm |
750×1200×675 |
800×1490×695 |
900×1765×760 |
| Inner tank size (W*H*D) mm |
600×620×420 |
650×890×440 |
750×1200×505 |
| Product weight |
125KG |
160KG |
210KG |
| Capacity |
155L |
255L |
455L |
| Total power for heating and humidification |
1550W |
2200W |
2300W |
| Refrigeration instructions |
250W.R134a |
250W.R134a |
550W.R134a |
| Humidity sensor |
Imported temperature and humidity sensor |
| Refrigeration method |
The cooling capacity of the compressor can be intelligently adjusted |
| Working environment temperature |
5ºC-35°C It is recommended to use the ambient temperature 10ºC-28°C |
| Power supply voltage |
AC-220V 50/60HZ |
| Safety device |
It features automatic start-up, automatic stop, power-on recovery, timed operation, and is equipped with compressor overpressure protection, over-temperature alarm, leakage protection, water shortage protection, door opening alarm, and sensor abnormality alarm functions |
| Stainless steel shelf |
Three floors (optional) |