Electronic Power Comprehensive Analyzer Transformer Load No-Load and No Load Tester
The MYRS-II Transformer Power Tester is a multifunctional measuring instrument that combines the capabilities of both a Transformer Capacity Tester and Transformer Characteristic Parameter Tester. This advanced device accurately measures power frequency parameters including capacity, type, no-load current, no-load loss, short-circuit (load) loss, and impedance voltage for various transformers.
This instrument features compact design, lightweight construction, high measurement accuracy, excellent stability, and simple operation. It completely replaces traditional multi-meter methods for measuring transformer loss and capacity, offering simplified wiring and convenient testing and recording capabilities that significantly improve work efficiency.
Key Features
- Accurate measurement of various distribution transformer capacity
- Comprehensive testing of no-load current, no-load loss, short circuit voltage, short circuit loss, and capacity
- Automatic range switching with wide voltage and current measurement ranges
- Three different meter testing methods
- Automatic wiring verification and three-phase voltage/current vector diagram display
- Full current load testing for transformers up to 1000kVA
- Automatic correction for waveform, temperature, non-rated voltage, and non-rated current
- High-brightness 320×240 LCD screen with brightness adjustment and touch button operation
- User-programmable storage for 40 test sample parameters
- Built-in real-time clock for automatic test date recording
- Integrated thermal printer for fast result printing
- Data storage for up to 500 test results with PC connectivity
- Extended range measurement capability using external voltage and current transformers
Technical Specifications
Test Capabilities
- Three-phase voltage RMS: Uab, Ubc, Uca
- Three-phase AC voltage average values: Uab, Ubc, Uca
- Three-phase current RMS: Ia, Ib, Ic
- No-load loss percentage and no-load current: Po, Io%
- Load loss, impedance voltage percentage, short circuit impedance: Pt, ekt, Zt
- Temperature-compensated load loss and impedance measurements
- Transformer actual capacity assessment and judgment
Environmental Conditions
| Temperature |
-5°C to 40°C |
| Relative Humidity |
<95% (at 25°C) |
| Altitude |
<2500m |
| External Interference |
No strong vibration or electromagnetic fields |
| Power Supply |
220VAC ±10%, 45Hz-55Hz |
Measurement Ranges
| Capacity |
10kV Oil-immersed/Dry-type: 30kVA-2500kVA 35kV Oil-immersed: 50kVA-31500kVA 20kV Dry-type: 50kVA-2500kVA 35kV Dry-type: 50kVA-2000kVA |
| Voltage |
0-450V (phase), 0-800V (line) with auto-ranging |
| Current |
0-100A with auto-ranging |
| Frequency |
45Hz-65Hz |
Measurement Accuracy
| Voltage |
20-100V: ±0.2%FS; 100-450V: ±(0.2%+3 digit) |
| Current |
0.5-10A: ±0.2%FS; 10-100A: ±(0.2%+3 digit) |
| Power |
±0.5% (CosΦ>0.1), ±1.0% (0.02<CosΦ<0.1) |
Insulation Strength
| Insulation Resistance |
Voltage/current input to shell ≥100MΩ |
| Withstand Voltage |
Power supply to shell: 2kV RMS, 1 minute |
Physical Specifications
| Dimensions |
400×300×220mm |
| Weight |
12kg (accessories not included) |