MY‑133 Portable Digital Ultrasonic Flaw Detector Handheld NDT Tester with Straight Probe & Angle Probe for Metal Weld Defect Inspection
| Technical Parameters | ||||
| Product Description | MY-U600 | MY-610 | MY-620 | MY-630 |
| Working principle | Ultrasonic | Ultrasonic | Ultrasonic | Ultrasonic |
| Working frequency | (0.2~20)MHz | (0.5~20)MHz | (0.5~20)MHz | (0.5~20)MHz |
| Pulse Width | Square wave width 30~1000ns adjustable, step 0.1ns | Square wave width 30~1000ns adjustable, step 0.1ns | Square wave width 30~1000ns adjustable, step 0.1ns | Square wave width 30~1000ns adjustable, step 0.1ns |
| Detection range | 0~14000 (Steel longitudinal wave)mm | 0~14000 (Steel longitudinal wave)mm | 0~14000 (Steel longitudinal wave)mm | 0~14000 (Steel longitudinal wave)mm |
| Pulse shift | -45~1000(steel longitudinal wave)mm | -45~1000(steel longitudinal wave)mm | -45~1000(steel longitudinal wave)mm | -45~1000(steel longitudinal wave)mm |
| Material sound velocity | 300~15000m/s | 300~15000m/s | 300~15000m/s | 300~15000m/s |
| Detection method | Negative wave, positive wave, two-way wave, filter, RF wave | Negative wave, positive wave, two-way wave, filter, RF wave | Negative wave, positive wave, two-way wave, filter, RF wave | Negative wave, positive wave, two-way wave, filter, RF wave |
| Gain adjustment | 0~110dB: 0.1/1/2/6 step adjustment | 0~110dB: 0.1/1/2/6 step adjustment | 0~110dB: 0.1/1/2/6 step adjustment | 0~110dB: 0.1/1/2/6 step adjustment |
| Thickness measurement function | non | non | Normal mode 0.75-300mm, penetration coating 2-150mm | Normal mode 0.75-300mm, penetration coating 2-150mm |
| WIFI/HDMI/digital filtering wave | non | non | non | Mobile phone connection/HD projection/digital filtering |
| Sluice gate | Incoming gate, loss gate; single gate reading, double gate reading | Incoming gate, loss gate; single gate reading, double gate reading | Incoming gate, loss gate; single gate reading, double gate reading | Incoming gate, loss gate; single gate reading, double gate reading |
| DAC,AVG Function | DAC curve,AVG curve | DAC curve,AVG curve | DAC curve,AVG curve | DAC curve,AVG curve |
| Attenuator error | Every 12dB+-1dB | Every 12dB+-1dB | Every 12dB+-1dB | Every 12dB+-1dB |
| Vertical linearity error | ≤3% | ≤3% | ≤3% | ≤3% |
| Horizontal linearity error | ≤0.5% | ≤0.5% | ≤0.5% | ≤0.5% |
| Dynamic Range | ≥30dB | ≥30dB | ≥30dB | ≥30dB |
| Sensitivity margin | ≥65dB (2.5Z20N Probe) | ≥65dB (2.5Z20N Probe) | ≥65dB (2.5Z20N Probe) | ≥65dB (2.5Z20N Probe) |
| Far zone resolution | ≥26dB | ≥26dB | ≥26dB | ≥26dB |
| Electrical noise level | ≤10(1~4MHz)% | ≤10(1~4MHz)% | ≤10(1~4MHz)% | ≤10(1~4MHz)% |
| Equivalent input noise | <80x10-9V/√Hz | <80x10-9V/√Hz | <80x10-9V/√Hz | <80x10-9V/√Hz |
| Pulse repetition frequency | 20~1000Hz,Stepping 25V | 20~1000Hz,Stepping 25V | 20~1000Hz,Stepping 25V | 20~1000Hz,Stepping 25V |
| Pulse voltage | 25~400V can adjust,step 25V | 25~400V can adjust,step 25V | 25~400V can adjust,step 25V | 25~400V can adjust,step 25V |
| Thin plate resolution | ≤3(5C10N Probe)mm | ≤3(5C10N Probe)mm | ≤3(5C10N Probe)mm | ≤3(5C10N Probe)mm |
| AWS D1.1/D1.5 | The AWS D1.1/D1.5 of the American Welding Association (AWS) calculates the weld level of steel structures and bridges | Support | Support | Support |
| Working voltage | 12V (Battery,DC) | 12V (Battery,DC) | 12V (Battery,DC) | 12V (Battery,DC) |
| Appearance size | 180x130x40mm (Height*Width*Depth) | 180x130x40mm (Height*Width*Depth) | 180x130x40mm (Height*Width*Depth) | 180x130x40mm (Height*Width*Depth) |
| Storage | Storage card | Storage card | Storage card | Storage card |
| Probe damping | 100Ω, 200Ω, 400Ω optional | |||
| Real-time sampling of hardware | High resolution 10-bit AD converter with sampling speed of 160MHz and high waveform fidelity | |||
| Detection method | Positive half wave, negative half wave, full wave, radio frequency detection | |||
| Filter band | (0.2~20)MHz, fully automatic matching according to probe frequency, no need to set manually | |||
| Communication Interface | USB2.0 high speed communication transmission interface | |||
| Ambient temperature and humidity | Temperature: (-10~50) °C Humidity: (20~95)%RH | |||

Shipping scenario
Scene (One)

Scene (Two)
Attachment Directory
| Qty | English Name | Remarks |
|---|---|---|
| 1 pc | Flaw Detector Host | Handheld main unit with color display |
| 1 pc | Angle Probe | For angle beam ultrasonic testing |
| 1 pc | Straight Probe | For normal beam ultrasonic testing |
| 1 pc | Power Adapter | AC power supply for the host |
| 1 pc | Data Cable | For waveform data export and PC connection |
| 1 pc | Support Rod | Auxiliary tool for probe operation |
| 1 set | Coupling Agent | For ultrasonic testing coupling |
| 1 set | Calibration Test Block | For instrument parameter calibration |
| 1 set | English User Manual | Operation guidance |
| 1 set | Calibration Certificate | Factory metrological calibration document |
| 1 pc | Portable Hard Carrying Case | For storage and transportation |
Attachment Image