The HZSP-II Gas Chromatograph (Touch Screen) is a laboratory-grade special gas chromatograph developed by our company. It features a 7-inch color touch screen control and a professional chromatography UI interface design that intuitively displays the inlet, column temperature box, detector internal temperature values, individual detector values, and running time. A one-key cooling function simplifies operation, making the instrument simple, intuitive, and easy to use.
The instrument is widely used in scientific research and education, petroleum, chemical industry, biochemistry, food safety, medicine and health, environmental monitoring, judicial investigation, and other fields. With high testing precision and good repeatability, the instrument is a trustworthy analytical solution.


| Network Inverse Control System | Internal CAN method with interface board design; can be converted to network output at will |
| Number of Signal Output Bits | 24-bit |
| Communication Interface | Network interface output (connected by Category 6 network cable) |
| Circuit Design | ARM embedded design; easy to realize wireless control, remote control, and cell phone APP control |
| Temperature Control System | Six independent temperature control |
| Temperature Control Range | Above room temperature to 450ºC; optional liquid nitrogen refrigeration: -80ºC to 450ºC |
| Column Temperature Control Accuracy | ±0.02ºC |
| Programmed Temperature Rise | Arbitrary order, 0.1 degree / order |
| Display Module | Large-screen liquid crystal display |
| Display Accuracy | 0.01ºC |
| Column Program Rise Rate | 0–80ºC/min (adjustment increment 0.1ºC/min), up to 120ºC/min |
| Programmed Temperature Rise Repeatability | ≤1% |
| Electronic Pressure Controller (EPC/EFC) | Pressure range: 0 ~ 1000 kPa; full pressure control accuracy: 0.001 psi; maximum shunt ratio: 8000:1 |
| TCD Detector Sensitivity | S value ≥ 8000 mv·ml/mg (benzene), up to 12000 mv·ml/mg (benzene) |
| TCD Baseline Noise | ≤10 uv |
| TCD Baseline Drift | ≤50 uv/30 min |
| FID Detector Detection Limit | ≤5.0 × 10⁻¹² g/s (cetane) |
| FID Baseline Noise | ≤ 2 × 10⁻¹⁴ A |
| FID Baseline Drift | ≤ 1 × 10⁻¹³ A/30 min (after 2 hours of instrument stabilization) |
| ECD Detector Detection Limit | ≤1.0 × 10⁻¹³ g/s (r-666) |
| ECD Baseline Noise | ≤40 uv |
| ECD Baseline Drift | ≤ 100 uv/30 min |
| FPD Detector Detection Limit | ≤1.4 × 10⁻¹² g/s (P), ≤5 × 10⁻¹¹ g/s (S) |
| FPD Baseline Noise | ≤ 20 uv |
| FPD Baseline Drift | ≤50 uv/30 min |
| Expansion | 6 external events can be added |
| Automation Engineering | Can add: automatic ignition function, autosampler connection, four-way flow pressure display function; optional reverse control workstation to realize reverse control |




We are an integrated trade and manufacturing company with our own factory.
Yes, we accept OEM/ODM/OBM and can customize the built-in software of the product according to the customer's special requirements.
In normal circumstances, products in stock can be received within 5 to 7 days via the fastest international express. Other situations may vary depending on the quantity of products ordered, whether there are special customization requirements, and the delivery time chosen.
We have professional internal and external packaging to ensure the safety and stability of the products during transportation. For fragile or other special parts, we will include an extra set to ensure that the customer can use the product immediately upon receipt.
For quality issues that are not caused by human error, we provide a one-year warranty from the time the product is delivered, and lifetime technical support. Other after-sales issues will be addressed by our professional technical staff within 24 hours. The product comes with a user manual and an operation video.