Specifications
Packaging Details :
IPPC Fumigated wooden box (lSPM15)
Control Box Output Voltage :
0-250V
Payment Terms :
T/T
Rated Output Capacity :
5kVA
Control Box Overall Dimension :
425mm × 288mm × 320mm
Brand Name :
HZRTZ POWER
MOQ :
1
Control Box Output Current :
25A
Leakage Current Range with Trip System :
≥30mA
Ambient Operating Temperature :
-10℃ ~ 40℃
Model Number :
HZNYZ-NT
Model NO. :
HZNYZ-NT
Rated Output Voltage :
50kv
Leakage Current Resolution :
0.01mA
Price :
USD 1,000 - 10,000
Place of Origin :
Wuhan, Hubei Province
Certification :
GB/T19001-2016 idt ISO 9001:2015
Delivery Time :
15-30 working days
Description
Product Overview

The HZNYZ-NT-II Automatic Withstand Voltage Tester for Insulating Boots & Gloves is developed and manufactured in compliance with the national standard DL/T1476-2015 Preventive Test Procedures for Electric Safety Tools. All performance indicators of this product meet the requirements of the national standard.

It performs intelligent insulation withstand voltage tests on safety tools such as insulating shoes and insulating gloves in accordance with the provisions of the Procedures. The test cycle for insulating boots and gloves is once every six months. No breakdown shall occur during the test, and the leakage current of insulating boots and gloves shall not exceed the specified limit values. This product is applicable to all power-related industries.

  • Resists high heat, humidity, and salt spray for tropical island use
  • Runs stably at -40°C, cold-proof and anti-condensation
  • IEC compliant, with complete calibration certificates provided
  • Local support: spares, on-site training, and instrument calibration
HZNYZ-NT Automatic Boots And Gloves Hipot Insulation Tester Safety Tools Withstand Voltage Test Equipment
Main Functions & Features
  1. The tester can test up to 8 insulating boots or gloves simultaneously and measure the leakage current of each test sample individually.
  2. A dry-type testing method with small steel balls placed inside insulating shoes is adopted for shoe testing, eliminating the traditional water-filling test method which leaves footwear hard to dry after testing.
  3. Real-time comparison between measured high voltage and low voltage ensures accurate readings of test voltage and leakage current.
  4. High-voltage and low-voltage circuits are isolated; leakage current data is transmitted back to the control box via anti-interference wireless transmission technology, greatly guaranteeing personal safety.
  5. Each test channel is equipped with an independent disconnect mechanism. If breakdown occurs or leakage current exceeds the preset limit on any single channel, that channel will automatically cut off without interrupting tests on other samples.
  6. Equipped with a 7-inch color touch screen with Chinese character display, presenting abundant data on one screen including test voltage, leakage current of 8 high-voltage channels, calendar, test timer, as well as Chinese operation prompts.
  7. A high-precision stepper motor regulates the voltage regulator for fully automatic withstand voltage testing. After test initiation, the equipment closes automatically, boosts voltage at the standard specified rate, holds the target voltage upon reaching the preset value and starts timing, reduces voltage automatically once timing finishes, cuts off power after voltage drops to zero, alerts test completion, displays leakage current of all samples, and automatically saves test records.
  8. Special metal grounding trays for insulating boot testing and dedicated containers for insulating glove testing are provided for convenient operation.
  9. The transformation ratio of the test transformer can be freely configured to match transformers already owned by customers.
  10. Built-in overcurrent protection function.
Technical Parameters
Item Specification
Input Power Supply 220V±10%, 50Hz
Control Box Output Voltage 0-250V
Control Box Output Current 25A
Rated Output Voltage 50kV
Rated Output Capacity 5kVA
Full-Scale Range of Leakage Current Indicator Meter 30mA
Leakage Current Range with Trip System ≥30mA
Voltage Measurement Error ±1% FS + 3 digits
Leakage Current Measurement Error ±1% FS + 3 digits
Leakage Current Resolution 0.01mA
Digital Timing Range Freely adjustable up to 9 minutes
Ambient Operating Temperature -10ºC ~ 40ºC
Ambient Humidity ≤90% RH, no condensation, no screen flicker
Continuous Operation Duration Max. 30 minutes with intermittent rest required
Control Box Overall Dimension 425mm × 288mm × 320mm
Test Bench Overall Dimension 1230mm × 400mm × 1450mm
Control Box Weight 20kg
Test Bench Weight 20kg
Standard Equipment Configuration
Serial No. Item Name Quantity
1 Main Instrument Unit 1 set
2 Test Bench 1 set
3 Operation Manual 1 copy
4 Product Quality Certificate 1 copy
5 Spare Thermal Printing Paper 2 rolls
6 Special Test Cables 2 pieces
7 Power Cord 1 piece
8 High-Voltage Cables 2 pieces
9 Grounding Cable 1 piece
10 Test Barrels for Insulating Gloves 8 units
11 Steel Balls for Dry Test 2 barrels
12 Test Transformer (5kVA / 50kV) 1 unit
Send your message to this supplier
Send Now

HZNYZ-NT Automatic Boots And Gloves Hipot Insulation Tester Safety Tools Withstand Voltage Test Equipment

Ask Latest Price
Packaging Details :
IPPC Fumigated wooden box (lSPM15)
Control Box Output Voltage :
0-250V
Payment Terms :
T/T
Rated Output Capacity :
5kVA
Control Box Overall Dimension :
425mm × 288mm × 320mm
Brand Name :
HZRTZ POWER
Contact Supplier
HZNYZ-NT Automatic Boots And Gloves Hipot Insulation Tester Safety Tools Withstand Voltage Test Equipment
HZNYZ-NT Automatic Boots And Gloves Hipot Insulation Tester Safety Tools Withstand Voltage Test Equipment
HZNYZ-NT Automatic Boots And Gloves Hipot Insulation Tester Safety Tools Withstand Voltage Test Equipment
HZNYZ-NT Automatic Boots And Gloves Hipot Insulation Tester Safety Tools Withstand Voltage Test Equipment
HZNYZ-NT Automatic Boots And Gloves Hipot Insulation Tester Safety Tools Withstand Voltage Test Equipment

Wuhan Hertz Power Equipment Co., Ltd

Verified Supplier
1 Years
wuhan
Since 2017
Business Type :
Manufacturer
Total Annual :
$10000000-$15000000
Employee Number :
100~120
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement