This three phase double wound distribution transformer delivers reliable and economical power conversion for small commercial facilities, retail properties, office buildings, and municipal installations. With a rated capacity of 30kVA and a voltage ratio of 20kV to 0.4kV, it forms the backbone of a stable low voltage supply in city and suburban distribution networks. The off circuit tap changer enables preset voltage ratio adjustments while the unit is de energized, allowing the transformer to match site specific primary voltage levels without the cost and complexity of on load mechanisms. Designed for long service life and minimal maintenance, this transformer supports both indoor dry type and outdoor oil immersed configurations, meeting a broad range of project specifications.
| Technical Feature | Specification and Description |
|---|---|
| Rated Capacity | 30 kVA, three phase, double wound, continuous duty. |
| Voltage Ratio | 20 kV (primary) to 0.4 kV (secondary) with galvanic isolation. |
| Core Material | Grain oriented cold rolled silicon steel, low loss grade, for reduced no load losses. |
| Winding Conductor and Type | Electrolytic copper or aluminum, layer and disc type construction ensuring uniform voltage distribution. |
| Off Circuit Tap Changer | Manually operated, accessible only when the transformer is completely de energized. Provides voltage ratio adjustment under no load conditions. |
| Typical Tapping Range | ±2x2.5% on the high voltage side, delivering five positions (e.g. 21kV, 20.5kV, 20kV, 19.5kV, 19kV) while maintaining 0.4kV output. |
| Cooling Method (Dry Type) | Natural air cooling (AN), with forced air (AF) option available. Suitable for indoor commercial settings. |
| Insulation Class (Dry Type) | Class F or H insulation system, VPI or encapsulated windings. Low smoke and self extinguishing materials for occupied buildings. |
| Cooling Method (Oil Immersed) | Natural oil cooling (ONAN) in a hermetically sealed corrugated tank, preventing moisture and oxygen ingress. |
| Insulating Fluid | High quality mineral oil or biodegradable ester fluid, optimised for outdoor and vault installations. |
| Voltage Regulation | Optimised impedance, typically 4%, to maintain statutory secondary voltage limits from no load to full load. |
| Sound Level Design | Step lap core joints with anti vibration damping coatings, delivering low sound pressure values suited to noise sensitive areas. |
| Thermal Performance | Designed to absorb repetitive load swings while keeping winding hot spot temperature well within insulation class limits. |
| Standards and Testing | Complies with IEC 60076 or equivalent. Routine tests include separate source voltage withstand, induced overvoltage, and temperature rise verification. |
| Connection and Enclosure Options | Flexible vector group (e.g. Dyn11), terminal box orientation, IP rating, and anti corrosion paint system as per project specification. |

Small commercial operations such as local retail businesses, banking branches, small office headquarters, and municipal pumping or lighting stations share distinct site constraints that this transformer is engineered to meet: