The Rebirth Pro™ 2 Thrombus Aspiration Catheter by Nipro is an advanced medical device designed for efficient removal of blood clots in cardiac and vascular interventions. It combines high-performance aspiration technology with user-centric design to support procedures such as percutaneous coronary interventions and thrombectomy in peripheral vessels. The system prioritizes procedural efficiency, safety, and compatibility with clinical workflows.
Key Features and Advantages
Powerful Aspiration Dynamics
Maintains a large, consistent inner lumen profile with cross-sectional areas of 0.97 mm² (6F) and 1.23 mm² (7F), enabling rapid and dynamic clot removal. This design minimizes flow resistance and reduces the risk of clot fragmentation.
The anti-kink braided shaft ensures stability in tortuous anatomy, preserving aspiration efficacy during complex maneuvers.
Superior Deliverability
A durable hydrophilic coating reduces friction during insertion into guide catheters and vasculature, facilitating smooth distal delivery. This coating enhances trackability while minimizing vessel trauma.
The extended 22cm guidewire lumen improves wire tracking and control, critical for navigating narrowed or curved vessels.
User-Friendly Workflow Integration
Dual-package system allows parallel preparation: one operator readies the catheter while another prepares accessories (e.g., filters, syringes), cutting setup time.
Pre-connected components (extension tube, 2-way stopcock, syringe) further streamline preparation. The inclusion of a 3-way stopcock enables simultaneous attachment of two 30mL syringes for double aspiration capacity.
Comprehensive Clot Management
Includes a large thrombus filter compatible with 500mL lab beakers and a small cell strainer for pathological analysis, supporting both procedural and diagnostic needs.
The system accommodates double aspiration techniques, enhancing efficiency in high-volume clot scenarios.
Workflow Optimization: Pre-configured components and dual-operator setup reduce preparation time by up to 50% in emergency settings.
The Rebirth Pro™ 2 exemplifies Nipro’s focus on integrating engineering precision with clinical practicality, offering a reliable solution for thrombus management in modern cath labs. Its design aligns with demands for speed, adaptability, and diagnostic support in interventional procedures.
Product tags
Send your message to this supplier
Send Now
Submission successful!
Nipro Rebirth Pro 2 Thrombus Aspiration Catheter Large Lumen and Hydrophilic Coating