It is an insertion-type flowmeter with high long-term stability, equipped with an integrated transmitter for easy operation.
- Gas: 1.0% of reading (10 to 100% of full scale), 0.1% of full scale (1 to 10% of full scale)
20 to 733,501 kilograms per hour (44 to 1,669,340 pounds per hour)
-40°C to 180°C (-40°F to 356°F)
-0.5 to 20 bar gauge (-7.25 to 290 psi gauge)
- Insertion tube material: Stainless steel, 1.4404 (316/316L)
- Process connections, process joints: Stainless steel, 1.4404 (316/316L)
- Sensing element:
- Unidirectional:
- Stainless steel, 1.4404 (316/316L)
- Alloy C22, 2.4602 (UNS N06022);
- Bidirectional:
- Stainless steel, 1.4404 (316/316L)
- Reverse flow detection: Stainless steel, 1.4404 (316/316L)
- Clamping ring: PEEK, PVDF, 1.4404 (316/316L)
- Flat ring seal: EPDM, FKM
- Proline t-mass F 300
- Proline t-mass A 150
- Proline t-mass B 150
- Proline t-mass F 500
- Proline t-mass I 300
- Proline t-mass I 500
- Proline t-mass T 150
- Industrial gas metering: Flow measurement of gas in steel plants and coking plants; monitoring of energy gases such as natural gas, liquefied gas, and flare gas.
- Environmental protection: Monitoring of chimney flue gas emissions (total control of SO₂ and NOₓ); flow control of aeration in sewage treatment.
- Semiconductor and chemical industry: Control of high-purity gases in epitaxial diffusion and coating processes; monitoring of reactor feeding and exhaust emissions.
- Medical and food industry: Gas flow control in oxygen concentrators and anesthesia machines; monitoring of gas filling in beverage bottling and carbon dioxide injection volume.