Specifications
Model Number :
SD2000
Technology :
Innovative RF Plasma,Low-Temperature Plasma
Payment Terms :
T/T
Usage :
saline irrgation,hemostasis,ablation,suction
Price :
Negotiable
Function :
Coblation,Puncture and Ablation,Hemostasis
Supply Ability :
1,000 units per month
Working Temperature :
40-70 ℃
Product name :
Advanced Arthroscopic Plasma Surgery System for Meniscectomy, Synovectomy & Sports Medicine Procedures
Certification :
CE, ISO13485
Charactor :
bipolar
MOQ :
1 Unit
Delivery Time :
2 working days
Product keywords :
rf plasma surgical electrode,otolaryngology head and neck plasma wand,ent china plasma surgery system,rf bipolar plasma surgery system machine
Instrument classification :
Class IIb
Place of Origin :
China
Feature :
Minimally Invasive,Less Pain,Low-Temperature,no bleeding
Packaging Details :
carton box
Factory :
Yes
Brand Name :
Golead
Properties :
Nose and Throat Surgical Instruments
Description
Advanced Arthroscopic Plasma Surgery System for Meniscectomy, Synovectomy & Sports Medicine Procedures
Advanced Low-Temperature Plasma Surgery System for Arthroscopy & Sports Medicine

This system is based on bipolar radiofrequency plasma technology, designed for minimally invasive orthopedic arthroscopic procedures including knee, shoulder, hip, and spine endoscopic surgery (UBE).

Unlike traditional electrosurgery, the system operates in a controlled low-temperature plasma field (approx. 40-70°C), enabling precise soft tissue ablation while minimizing collateral thermal damage.

The technology is widely used in:

  • Meniscectomy (partial or complete)
  • Synovectomy
  • Ligament debridement & release
  • Cartilage reshaping (chondroplasty)
  • Soft tissue ablation in arthroscopy
What is RF Plasma Coblation Technology

RF plasma coblation is a bipolar energy-based surgical technology that uses radiofrequency energy in a conductive saline medium to create a controlled plasma field at the electrode tip.

This plasma field contains highly energized particles that break molecular bonds within soft tissue at a relatively low temperature of 40°C-70°C, enabling precise tissue ablation with minimal thermal damage to surrounding structures.

Compared with traditional electrosurgical systems that rely on high-temperature thermal cutting, coblation technology offers a more controlled and tissue-preserving surgical effect.

How Plasma Coblation Works in Arthroscopic Surgery

The system generates a conductive plasma field in saline environment. The energized ions break molecular bonds of soft tissue at a relatively low temperature compared with traditional electrosurgery.

This allows:

  • Precise tissue removal layer by layer
  • Minimal thermal spread to surrounding cartilage
  • Reduced postoperative inflammation
  • Faster rehabilitation for sports medicine patients
Technical Parameters
Input Voltage 220V/50-60Hz 4A
Export device could convert automatically per customer requirements
Output Power Ablation and resection: ≤360W
Coagulation and hemostasis: ≤110W
Working Frequency 100 KHz ± 10%
Dimensions 415*365*105mm (L*W*H)
Working Mode Ablation and resection: level 1-9
Coagulation: level 1-6
Weight 10kg
Clinical Alignment

Clinical Applications Aligned With Modern Arthroscopy Standards

This system is designed to support procedures consistent with modern minimally invasive orthopedic guidelines, including:

  • ACL and meniscus related soft tissue management
  • Shoulder impingement and synovial resection
  • Hip arthroscopy debridement
  • UBE spine decompression procedures
Safety & Control Advantages
  • Low-temperature controlled ablation reduces thermal injury risk
  • Bipolar energy delivery minimizes lateral tissue damage
  • Real-time energy adjustment for different tissue types
  • Clear surgical field with reduced smoke formation
  • Compatible with standard arthroscopic saline irrigation systems
System Capabilities
  • Tissue ablation
  • Resection
  • Coagulation
  • Hemostasis
  • Suction-assisted removal
Coblation vs Traditional Electrosurgery
Feature RF Plasma Coblation Traditional Electrosurgery
Working Temperature 40-70°C 200-400°C+
Tissue Damage Minimal Significant thermal injury
Bleeding Control Precise coagulation Higher thermal spread
Healing Time Faster recovery Longer recovery
Precision in Small Areas High Moderate
Comparable Systems in the Market

This system offers similar functional principles to leading coblation platforms such as:

  • Smith+Nephew COBLATION systems
  • ArthroCare plasma surgical platforms

While maintaining a more flexible OEM-friendly cost structure for hospitals and distributors.

Quality & Safety
  • CE & ISO 13485 manufacturing system
  • Stable plasma output control
  • Temperature regulation validation (40-70°C)
  • Medical-grade system components
Why Choose This System
  • Compatible with standard arthroscopic OR setups
  • Supports multiple surgical indications in one system
  • Reduces OR time through integrated ablation & coagulation
  • Consumable probe design supports recurring revenue model
  • Cost-effective alternative to premium Western systems
Ready to Evaluate Our Plasma Surgery System?
  • Get Full Technical Datasheet
  • Request Pricing
  • Arrange Product Demo
  • Talk to Application Specialist
Frequently Asked Questions
Q1: Is this system suitable for meniscus and synovectomy procedures?

Yes. It is designed for arthroscopic soft tissue ablation including meniscus trimming, synovial tissue removal, and ligament debridement.

Q2: What is the working temperature of the system?

The system operates at a controlled low temperature range of approximately 40-70°C to minimize thermal damage.

Q3: Can it be used in UBE spine surgery?

Yes. The system is compatible with biportal endoscopic spine procedures for soft tissue ablation and decompression.

Q4: Is the system compatible with standard arthroscopy setups?

Yes, it is designed for standard arthroscopic saline environments and OR configurations.

Q5: Do you provide disposable probes?

Yes, compatible disposable probes are available for different surgical applications.

Clinical Images
Low-Temperature Minimally Invasive Arthroscopic Plasma Surgery System with 40-70 ℃ Working Temperature for RF Plasma Surgical Electrode Low-Temperature Minimally Invasive Arthroscopic Plasma Surgery System with 40-70 ℃ Working Temperature for RF Plasma Surgical Electrode
Send your message to this supplier
Send Now

Low-Temperature Minimally Invasive Arthroscopic Plasma Surgery System with 40-70 ℃ Working Temperature for RF Plasma Surgical Electrode

Ask Latest Price
Model Number :
SD2000
Technology :
Innovative RF Plasma,Low-Temperature Plasma
Payment Terms :
T/T
Usage :
saline irrgation,hemostasis,ablation,suction
Price :
Negotiable
Function :
Coblation,Puncture and Ablation,Hemostasis
Contact Supplier
Low-Temperature Minimally Invasive Arthroscopic Plasma Surgery System with 40-70 ℃ Working Temperature for RF Plasma Surgical Electrode
Low-Temperature Minimally Invasive Arthroscopic Plasma Surgery System with 40-70 ℃ Working Temperature for RF Plasma Surgical Electrode

Golead Medical Group Co.,Ltd

Verified Supplier
4 Years
sichuan, chengdu
Since 2010
Business Type :
Manufacturer, Distributor/Wholesaler
Total Annual :
30,000,000-50,000,000
Employee Number :
200~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement