Specifications
Brand Name :
HICORPWELL
Model Number :
FSI-600-05 Energy Optic Fiber Cable
Certification :
IEC 60794-2-10/11
Place of Origin :
China
MOQ :
1set
Price :
negotiation
Payment Terms :
Western Union, L/C, T/T
Supply Ability :
5000pcs Per Week
Packaging Details :
Individual package
Keyword :
FSI-600-05 Energy Optic Fiber Cable
Connector :
FSI-600-05
Operating wavelength :
1310, 1490,1550 nm
Length :
5M
Fiber Type :
single mode / multimode
MOQ :
1 pcs
Leadtime :
3-5 working days
Description

FSI-600-05 Repair High Power Fiber Laser Fiber Laser FSI-400-05 FSI-600-05 Repair High Power Fiber

We are profesionnal in laser component,Laser welding optical fiber, laser fiber for Mitsubisi ST200E ST300E ST400E ST600F fiber,

Miyaki SIH-04CA05M SIH-06CA05M GIH-04CA05M GIH-06CA05M,Hans laser FSI-400-05 FSI-600-05.

Here is the English version of the product information, organized to explain the brands, product series,

and potential application directions for a quick understanding of these fiber

ST200E / ST300E / ST400E / ST600F Series Fibers,As a renowned Japanese industrial brand,

Mitsubishi's fiber products are widely used in laser transmission, industrial processing, medical equipment, etc.,

known for high durability and transmission stability.

ST200E / ST300E / ST400E**: - "ST" may stand for "Standard Type",

"200/300/400" likely refers to the core diameter (unit: μm),

"E" may indicate specific coating materials or application scenarios

Suitable for medium and low - power laser transmission,

such as laser marking, welding, or medical laser equipment.

Larger core diameters allow higher power transmission.

- **ST600F**: - "600" refers to a 600μm large core diameter,

"F" may mean "Flexible" or "High Power".

It is suitable for high - power laser transmission (e.g., industrial cutting, welding),

with a flexible design for complex optical path layouts. -

Laser processing equipment, medical laser instruments, industrial automation optical systems.

SIH - 04CA05M / SIH - 06CA05M / GIH - 04CA05M / GIH - 06CA05M

Miyaki, possibly a niche Japanese precision optics brand, focuses on micro - fibers,

special - purpose fiber connectors, etc., commonly used in semiconductor manufacturing and precision optical instruments.

**SIH - 04CA05M / SIH - 06CA05M**: - "SIH" may represent "Single - Clad Infrared" fiber,

"04/06" refers to core diameters of 400μm/600μm, "CA" may indicate coating materials (e.g., ceramic, metal armor),

and "05M" means a length of 5 meters. - Suitable for infrared laser transmission (e.g., CO₂ laser, fiber laser),

with a single - clad structure for medium and low - power scenarios.

- "GIH" may stand for "Gradient Index Infrared" fiber. Compared with the SIH series, the gradient index design reduces

light loss and improves transmission efficiency, making it suitable for scenarios requiring high beam quality

(e.g., precision laser processing, spectral analysis).

Semiconductor laser equipment, infrared spectrometers, precision laser processing heads.

1. FSI - 400 - 05 / FSI - 600 - 05** - **Brand & Positioning**: Hicorpwell ,a leading Chinese laser equipment manufacturer,

designs its fiber products to integrate with its own laser systems, mainly for industrial laser processing equipment.

- **Model Analysis**: - "FSI" likely means "Fiber System for Industrial", "400/600" refers to core diameters of 400μm/600μm,

and "05" indicates a length of 5 meters. - supporting high - power laser transmission (e.g., in fiber laser cutting and welding machines),

and may feature bend resistance and high - power density tolerance.

Features:

Sapphire protected connector;
Protective layer of high quality stainless steel armored hose;
Large core power fiber;
Advanced non adhesive process;
A variety of specifications optional.

Application:

High power laser flexible transmission;
Laser welding and cutting;
Laser marking;
Atmospheric spectrum measurement;
Laser cleaning.

Fiber parameters

parameter Specification
Product model(µm) HCW200E HCW300E HCW400E HCW600F
Core diameter(µm) 200 300 400 600
Cladding diameter(µm) 500 500 500 750
Coating diameter 780 780 780 1100
Core material Pure quarta(Low-OH)
Cladding material Doped quartz material
Numerical aperture(NA) 0.22
Two cladding numericail(NA) NA 0.37 OR NA 0.46
Operating wavelength(nm) 400-2400
Length(m) 3, 5, 10(the default length is 5 meters, which can be customized)

Hicorpwell Laser Fiber Hans Laser FSI-400-05 FSI-600-05 Repair High Power FiberHicorpwell Laser Fiber Hans Laser FSI-400-05 FSI-600-05 Repair High Power FiberHicorpwell Laser Fiber Hans Laser FSI-400-05 FSI-600-05 Repair High Power Fiber

Send your message to this supplier
Send Now

Hicorpwell Laser Fiber Hans Laser FSI-400-05 FSI-600-05 Repair High Power Fiber

Ask Latest Price
Watch Video
Brand Name :
HICORPWELL
Model Number :
FSI-600-05 Energy Optic Fiber Cable
Certification :
IEC 60794-2-10/11
Place of Origin :
China
MOQ :
1set
Price :
negotiation
Contact Supplier
video
Hicorpwell Laser Fiber Hans Laser FSI-400-05 FSI-600-05 Repair High Power Fiber
Hicorpwell Laser Fiber Hans Laser FSI-400-05 FSI-600-05 Repair High Power Fiber
Hicorpwell Laser Fiber Hans Laser FSI-400-05 FSI-600-05 Repair High Power Fiber
Hicorpwell Laser Fiber Hans Laser FSI-400-05 FSI-600-05 Repair High Power Fiber

Shenzhen Hicorpwell Technology Co., Ltd

Verified Supplier
8 Years
guangdong, shenzhen
Since 2013
Business Type :
Manufacturer, Importer, Exporter
Total Annual :
3,000,000-5,000,000
Employee Number :
160~166
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement