Automatic Start 60Hz 110KW 140KVA 3 Phase Biogas Generator With CE Approvement
OPERATOR RESPONSIBILITY
- Know how to stop the generator quickly in case of emergency.
- Understand the use of all generator controls, input and output, and connections.
- Be sure that anyone who operates the generator receives proper instruction. Do not let children operate the generator. Keep children and pets away from the area of operation.
- Place the generator on a firm, level surface and avoid loose sand or snow. If the generator is
Control module has indicators for failure information:
Over-speed/under-speed,
Emergency stop
Low oil pressure;
High water temperature
Failure to start
Overload
Mains failure
Synchronization failure
Speed governing limit
Phase missing
Optional at
Soundproof type
Weather proof type,
Container type
Main Specifications
| Item | Model | SP120B | |
| fuel | — | Biogas | |
| marks | — | Synchro Genset | |
| CHP | electrical output(KWe) | kVA/kWe | Continuous Power |
| 137.5/110 | |||
| frequency | Hz | 60 | |
| voltage | V | 400/230 | |
| gas inlet pressure | kPa | 1-10 | |
| dimension (soundproof type) | mm*mm*mm | 2600*1550*1650 | |
| net weight | kg | 3000 | |
| Biogas consumption | m3/kW.h | 0.45 | |
| Biogas consumption for one hours | m3/h | 49.5 | |
| db(A)@7m | — | 58 | |
| Certificate | — | CE | |
| ignition system | — | Impco | |
| speed governor | — | Woodward | |
| gas filter | — | Madas | |
| zero regulator | — | Kromschroeder | |
| MCB | — | ABB | |
| GCB | — | ABB | |
| Controller | ComAp/CZ | ||
| Engine | Engine model | — | SP-6LTA |
| Engine type | — | 6 cylinders,4stroke,water-coolled | |
| RPM | — | 1800 | |
| Compression Ratio | — | 10.5 | |
| Displacement | — | 8.9L | |
| Oil capacity | — | 27L | |
| Charging voltage | — | 24V(DC) | |
| Charging current | — | 5A(DC) | |
| Starting system | — | Electic-start | |
| Alternator | model | — | Meccalte |
| phase | — | 3 phase 4 wires | |
| insulation system | — | class H | |
| protection | — | IP23 | |
| Cooling Type | — | air cooled |
Biogas Requirements
| Composition | Content |
| CH4 | ≥55% |
| fluctuations value of biogas in pipeline | <0.2Kpa |
| hydrogen | <10% |
| sulfide, including hydrogen sulphide | <200mg/m3 |
| chlorine fluorine compounds,mainly chlorofluoromethane | <15mg/m3 |
| silicium | <0.7mg/m3 |
| ammonia | <15mg/m3 |
| liquid oil and hydrocarbons | <50mg/m3 |
| particles | <5μm Impurity content<30mg/m3 |
For more information about the generator, please consult with your sales representative.Thanks.