 CHP Main Specifications
| Model | SP130B | |
| fuel | — | Biogas | 
| marks | — | Synchro CHP | 
| electrical output(KWe) | kVA/kWe | Continuous Power | 
| 162/130 | ||
| thermal output(KWe) | kWt | 194 | 
| electrical efficiency | % | 33.2% | 
| thermal efficiency | % | 49.6% | 
| overall efficiency | % | 82.8% | 
| frequency | Hz | 50 | 
| voltage | V | 400/230 | 
| gas inlet pressure | kPa | 3-5 | 
| dimension (soundproof type) | mm*mm*mm | 2900*1600*1800 | 
| net weight | kg | 3500 | 
| Biogas consumption | m3/kW.h | 0.42 | 
| Biogas consumption for one hours | m3/h | 54.6 | 
| db(A)@7m | — | 59 | 
| Certificate | — | CE | 
| water-water heat exchanger | — | SWEP | 
| water-exhaust heat exchanger | — | made of stainless steel | 
| ignition system | — | Impco | 
| speed governor | — | Woodward | 
| gas filter | — | Madas | 
| zero regulator | — | Kromschroeder | 
| MCB | — | ABB | 
| GCB | — | ABB | 
| Controller | ComAp | |
| Engine model | — | STYER T10 | 
| Engine type | — | 6 cylinders,4stroke,water-coolled | 
| RPM | — | 1500 | 
| Compression Ratio | — | 11.0 | 
| Displacement | — | 9.726L | 
| Oil capacity | — | 24L | 
| Charging voltage | — | 24V(DC) | 
| Charging current | — | 5A(DC) | 
| Starting system | — | Electic-start | 
| model | — | Meccalte | 
| phase | — | 3 phase 4 wires | 
| insulation system | — | class H | 
| protection | — | IP23 | 
| Cooling Type | — | air cooled | 
 
 Characters
  
 Environmentally friendly design.
 Long time R&D and testing ensure high reliability.
 Comprehensive heat insulation to minimize heat loss.
 CHP inner pipelines are made of full stainless steel material.
 Maximum lower the noise level.
 Maintenance friendly thanks to easy access.
  
 Biogas Requirements
| Composition | Content | 
| CH4 | ≥55% | 
| fluctuations value of biogas in pipeline | <0.2Kpa | 
| hydrogen | <10% | 
| sulfide, including hydrogen sulphide | <200mg/m3 | 
| chlorine fluorine compounds,mainly chlorofluoromethane | <15mg/m3 | 
| silicium | <0.7mg/m3 | 
| ammonia | <15mg/m3 | 
| liquid oil and hydrocarbons | <50mg/m3 | 
| particles | <5μm Impurity content<30mg/m3 | 
 
 
  