Specifications
Number of Cores :
1 Core
Supply Ability :
800-1500 Kilometers per Month
Size :
10 AWG
Packaging Details :
Wooden drum, cardboard box or wooden pallet
Standard :
UL 83
Conductor :
Stranded / Solid Bare Copper
Place of Origin :
China
MOQ :
1000 Meters
Rated Voltage :
600V
Abrasion Resistance :
Yes
Brand Name :
F.T
Payment Terms :
T/T,L/C,Western Union
Model Number :
THHN 10 AWG
Jacket :
Nylon
Certification :
UL, RoHS
Delivery Time :
7-15 Working Days
Insulation :
PVC (Polyvinyl Chloride)
Price :
USD 0.25-0.55 / Meter
Temperature Rating :
90C Dry / 75C Wet
Oil Resistance :
Yes
Application :
Conduit & Raceway Wiring
Description

10 AWG THHN Cable — 600V, PVC Insulation + Nylon Jacket, Oil & Abrasion Resistant

This 10 AWG THHN cable is a 600V rated building wire with PVC insulation and a tough nylon jacket. Rated for 90°C dry locations, it resists oil, abrasion, heat and chemicals, making it an ideal choice for conduit and raceway wiring in residential, commercial and industrial power distribution.

Key Selling Points

  • 600V Rated — suitable for general-purpose branch-circuit and feeder electrical applications.
  • 90°C Dry Location — high heat resistance for enclosed indoor installation.
  • PVC Insulation + Nylon Jacket — durable dual-layer protection with low smoke and flame retardant performance.
  • Oil & Abrasion Resistant — resists oil, grease, chemicals and mechanical wear.
  • For Conduit & Raceway Wiring — flexible and easy to pull, reducing installation time.

10 AWG THHN Cable 600V PVC Nylon Jacket 90C Dry Location Oil Resistant for Conduit Raceway Wiring

Specification

Item Value
Size 10 AWG
Conductor Stranded / solid bare copper (7 strands)
Insulation Thickness 20 mils (PVC)
Nylon Jacket Thickness 4 mils
Nominal Outer Diameter 1.27 inch
Rated Voltage 600V
Temperature Rating 90°C dry / 75°C wet
Standard UL 83
Component
Material
Function
Conductor
Copper (Solid or Stranded)
Provides excellent electrical conductivity.
Insulation
PVC (Polyvinyl Chloride)
Protects against environmental factors and physical wear.
Outer Jacket
Nylon
Enhances durability and eases installation by enabling smooth pulling.

MM2

AWG
Diameter of
conductor

Min. No of wire

Insulation Thickness

Jacket Thickness

Diam.

Approx. Wt.
-
-
-
mm
n
mm
mm
mm
Kg/km
2.08
14
AWG
1.85
7
0.38
0.1
2.8
25
3.31
12
AWG
2.32
7
0.38
0.1
3.3
37
5.26
10
AWG
2.95
7
0.51
0.1
4.2
59
8.37
8
AWG
3.71
7
0.76
0.13
5.5
96
13.3
6
AWG
4.67
7
0.76
0.13
6.5
145
21.2
4
AWG
5.89
7
1.02
0.15
8.2
232
26.7
3
AWG
6.60
7
1.02
0.15
8.9
285
33.6
2
AWG
7.42
7
1.02
0.15
9.8
352
42.4
1
AWG
8.43
19
1.27
0.18
11.3
452

Properties of THHN Wire
* Heat Resistance: Handles temperatures up to 90°C in dry locations.
* Resilience to Adverse Conditions: Resistant to moisture, gasoline, and certain chemicals.
* Ease of Installation: The nylon jacket creates a smooth surface, easing pulling through conduits.
* Variety of Gauge Sizes: Available in a range of sizes from 1000 MCM to 14 AWG.
* Color-Coding for Safety: Simplifies identification and enhances safety in complex wiring systems.

Uses of THHN Wire
* Conduit and Cable Trays: Commonly used for service, feeder, and branch circuits.
* Lighting Fixtures: Reliable for wiring up lighting fixtures due to its conductivity and heat resistance.
* Heating Units and Air Conditioners: Suitable for high-temperature environments.
* Control Circuits: Ensures optimal functionality for appliances and machinery.
* Machine Tools: Ideal for challenging environments where moisture or high temperatures are present.

Applications

Residential & house internal wiring · Commercial buildings, hotels and office buildings · Industrial plant and factory power distribution · Conduit, duct and raceway wiring · Control panels and switchboards.

10 AWG THHN Cable 600V PVC Nylon Jacket 90C Dry Location Oil Resistant for Conduit Raceway Wiring

FAQ

Q: What is THHN cable?
A: Thermoplastic High Heat-resistant Nylon-coated wire, a 600V building wire with PVC insulation and a nylon jacket.
Q: Is it suitable for wet locations?
A: It is primarily rated for dry locations at 90°C; UL 83 also permits 75°C wet-location use within specific installation conditions.
Q: Do you provide certificates and samples?
A: We supply UL and RoHS certificates with factory test reports; samples are free of charge.

Send your message to this supplier
Send Now

10 AWG THHN Cable 600V PVC Nylon Jacket 90C Dry Location Oil Resistant for Conduit Raceway Wiring

Ask Latest Price
Number of Cores :
1 Core
Supply Ability :
800-1500 Kilometers per Month
Size :
10 AWG
Packaging Details :
Wooden drum, cardboard box or wooden pallet
Standard :
UL 83
Conductor :
Stranded / Solid Bare Copper
Contact Supplier
10 AWG THHN Cable 600V PVC Nylon Jacket 90C Dry Location Oil Resistant for Conduit Raceway Wiring
10 AWG THHN Cable 600V PVC Nylon Jacket 90C Dry Location Oil Resistant for Conduit Raceway Wiring
10 AWG THHN Cable 600V PVC Nylon Jacket 90C Dry Location Oil Resistant for Conduit Raceway Wiring
10 AWG THHN Cable 600V PVC Nylon Jacket 90C Dry Location Oil Resistant for Conduit Raceway Wiring

F. T Cable Co., Ltd.

Verified Supplier
1 Years
Shaanxi
Since 2024
Business Type :
Manufacturer
Total Annual :
15Million-60Million
Employee Number :
200~250
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement