Specifications
Safety :
High
Nitrogen Pressure of Driving De vice :
6.0±1.0Mpa(20℃)
Brand Name :
Guangzhou Xingjin Fire Equipment Co.,Ltd.
Product Name :
Novec 1230
Model :
QMP40/4.2, QMP70/4.2, QMP100/4.2, ......
Material :
Steel
Filling density :
≤950kg/m3,≤1080kg/m3
MOQ :
1 set system
Transport Package :
Plywood Outer Box With Bubble Bag Or Paper
Discharge Time :
≤10s
Payment Terms :
T/T,L/C
Supply Ability :
30000 sets per month
Certification :
CCC,ROHS,CAC
Delivery Time :
15-20days
Model Number :
QMP40/4.2, QMP70/4.2, QMP100/4.2, ......
max working pressure :
5.3Mpa/8.0Mpa
Price :
Pricing based on quantity
Place of Origin :
Guangzhou, Guangdong, China
Storage Medium :
Novec 1230, FK-5-1-12, C6F12O
Condition of reserving room for container :
temperature: -10~50℃, relative humidity: ≤97%
Mini Order :
1 Set
min working pressure :
4.2Mpa/4.6Mpa
Packaging Details :
Plywood outer box with bubble bag or paper
Description

Novec1230 (FK-5-1-12) pipe network automatic fire suppression system is a clean agent fire protection solution using an eco-friendly fluorinated ketone extinguishing agent. Specifically designed for data centers, telecom base stations, factory control rooms, hospitals, and commercial complexes, this system achieves full flooding discharge within 10 seconds. It leaves no residue, is non-conductive, and causes no harm to personnel or equipment, making it an ideal replacement for traditional Halon fire suppression systems.


Why Choose Novec1230 Pipe Network System

  • High Temperature & Humidity Tolerance
    Operates reliably at 0~50°C with relative humidity up to 97%, suitable for most climate conditions

  • Power Supply Compatibility
    Powered by DC24V/1.6A, compatible with UPS and backup power systems commonly used in facilities.

  • Environmentally Compliant
    Zero ODP and GWP of 1 with no halogen additives, aligning with CPCB guidelines for environmentally friendly fire extinguishing agents.

  • Local Certification Support
    Cylinders, piping, and valves can be configured to meet BIS standards and local fire department technical review requirements.
    Novec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression SystemNovec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression System


Typical Applications

This system is widely recommended for the following commercial and industrial environments :



Application Specific Use Cases
Data Centers & IT Rooms Third-party data centers and enterprise server rooms in Bangalore, Hyderabad, Pune, Mumbai, Chennai, Delhi-NCR
Telecom Infrastructure BTS towers, switching centers, mobile communication hubs
Banks & Financial Institutions State bank headquarters, data centers, vaults, ATM control rooms
Healthcare Facilities Operating theaters, MRI rooms, pharmaceutical storage in large private hospitals and diagnostic centers
Manufacturing & Industrial Control Rooms Central control rooms and electrical rooms in automotive, pharmaceutical, chemical, and textile plants
Metro & Rail Transit Metro control centers, signal rooms, substations
Commercial Complexes & High Rise Buildings Electrical rooms and server rooms in shopping malls, hotels, office towers
Energy & Power Facilities Power plant control rooms, substations, battery rooms
Novec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression System


Key Advantages

  • Fast Fire Suppression
    Complete agent discharge in ≤10 seconds for rapid fire control, minimizing business interruption.

  • Clean & Residue Free
    No cleanup required after discharge, preventing secondary damage to electronics or valuable assets.

  • Safe for Occupied Areas
    Harmless at recommended design concentrations, with an adjustable time delay (approx. 2 minutes) for safe evacuation.

  • Environmentally Friendly
    Zero ODP and GWP of 1 with no atmospheric lifetime restrictions, supporting green building initiatives.

  • Multi Zone Protection
    A single system can protect multiple independent zones using selector valves, significantly reducing equipment costs.

  • Broad Fire Class Coverage
    Effective against Class A (solids), Class B (liquids), Class C (gases), and electrical fires.


Technical Specifications



Parameter 4.2MPa System 5.6MPa System
Filling Pressure 4.2MPa 5.6MPa
Max Protected Area per Zone ≤800m² ≤800m²
Max Protected Volume per Zone ≤3600m³ ≤3600m³
Discharge Time ≤10 seconds ≤10 seconds
Filling Density ≤0.95kg/L ≤1.08kg/L
Operating Voltage DC24V/1.6A DC24V/1.6A
Nitrogen Driving Pressure 6.0±1.0MPa (20°C) 6.0±1.0MPa (20°C)
Cylinder Capacity 40L / 70L / 100L / 120L / 150L / 180L 70L / 90L / 120L
Max Working Pressure 5.3MPa 8.0MPa
Storage Temperature 0~50°C 0~50°C
Relative Humidity ≤97% ≤97%

System Components

  • Agent Storage Cylinders – Pressure vessels containing Novec1230 agent

  • Nitrogen Actuation Cylinders – Releases the cylinder valve to discharge agent

  • Selector Valves – Enables multi-zone selective discharge

  • Pipe Network – High pressure galvanized steel pipes and fittings

  • Nozzles – Evenly distributes extinguishing agent throughout the protected area

  • Fire Alarm Control Panel – Detection, alarm, and actuation control

  • Detectors – Smoke and heat detection devices
    Novec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression SystemNovec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression SystemNovec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression System


Market Support Services

  • Engineering drawings compliant with electrical and fire safety standards

  • Technical documentation support for local fire department approval and commissioning

  • Local stock of common cylinder sizes and pipe fittings in Mumbai / Delhi / Bangalore

  • Remote commissioning guidance and on-site technical support

  • Engineer dispatch available for on-site system commissioning and operator training


FAQ

Q: Does the system require local certification?
A: Main components can be configured to meet BIS and local fire code requirements. We provide technical documentation to assist with local approvals.

Q: How often do cylinders need inspection?
A: Hydrostatic pressure testing and air tightness inspection is recommended every 5-6 years. Follow local fire department guidelines for specific requirements.

Q: How to refill the agent after discharge?
A: Cylinders can be returned to us or authorized partners for refilling, or you may use qualified local refilling service providers.

Send your message to this supplier
Send Now

Novec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression System

Ask Latest Price
Watch Video
Safety :
High
Nitrogen Pressure of Driving De vice :
6.0±1.0Mpa(20℃)
Brand Name :
Guangzhou Xingjin Fire Equipment Co.,Ltd.
Product Name :
Novec 1230
Model :
QMP40/4.2, QMP70/4.2, QMP100/4.2, ......
Material :
Steel
Contact Supplier
video
Novec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression System
Novec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression System
Novec1230 (FK-5-1-12) Pipe Network Automatic Fire Suppression System

Guangzhou Xingjin Fire Equipment Co.,Ltd.

Verified Supplier
11 Years
guangdong, guangzhou
Since 2010
Business Type :
Manufacturer, Exporter
Total Annual :
600000-1200000
Employee Number :
100~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement