Specifications
Model Number :
J-SAP-JBF4121A
Temperature :
-10℃ to +55℃
MOQ :
100 set system
Delivery Time :
15-20days
Working Voltage :
DC19-28V
Light Intensity :
135cd
Alarm Concentration :
0.65~15.5%FT
Certification :
CCC;GB/T 3836.1-2021;GB/T 3836.4-2021;GB 19880-2005
Installation :
Wall mounting
Packaging Details :
Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Operatingtemperaturerange :
-10°C to 50°C
Payment Terms :
T/T,L/C
Bus Voltage :
DC 14V ~ DC 24V
Nominal Diameter :
15mm, 20mm
Maintenance :
Monthly Testing Recommended
Brand Name :
XINGJIN
Poe :
Optional
Place of Origin :
Guangzhou,China
Power :
Battery
Price :
USD3-4/pc
Minimum Oeder Quantity :
1set
Power Voltage :
DC 24V
Supply Ability :
300000 sets per month
Indicated Light :
Red (Alarm/Failed), Green (Running)
Usage :
Fire alarm display and alarming
Description
Product Overview

In automatic mode, when any detector senses a fire, it immediately transmits a signal to the control panel. The control panel then activates the audible and visual alarm devices, starts the exhaust fans, disconnects non-essential power supplies, and sends a command to recall all elevators. If a person discovers the fire, they can press a manual call point to trigger the same sequence.

For areas protected by a gas-based fire suppression system, the release sequence begins only after two independent detectors have been activated. Once this condition is met, a pre-determined delay timer starts. After the delay elapses, the extinguishing gas is released, and the release indicator lights illuminate to clearly warn people not to enter the protected area. All these functions work tog to ensure fast fire detection and safe occupant evacuation.

Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
System Architecture
1. Detection Layer (Sensors)

The detection layer acts as the sensory system of the fire alarm installation. It includes smoke detectors, heat detectors, and combined smoke-and-heat detectors.

  • Smoke detectors sense changes in air caused by combustion and are ideal for offices, hotels, and corridors.
  • Heat detectors monitor temperature increases and are well suited for kitchens, car parks, and plant rooms.
  • Combined detectors use both smoke and heat sensing to reduce false alarms, making them a preferred choice for hospitals and premium commercial buildings.
  • Beam smoke detectors are recommended for large-volume spaces such as warehouses, atriums, and sports stadiums.
  • Flame detectors should be used in high-risk areas, including oil depots, fuel storage zones, and chemical plants.
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
2. Input Layer (Manual and Monitoring Equipment)

This layer enables manual initiation and external equipment monitoring. It consists of manual call points, input modules, short-circuit isolators, and fire telephone sockets.

  • Manual call points are installed near exits, staircases, and common areas, allowing anyone to manually trigger an alarm.
  • Input modules receive status signals from external devices, such as water flow switches, pressure switches, and control valves.
  • Short-circuit isolators automatically disconnect faulty sections of the loop, ensuring the rest of the system remains operational.
  • Fire telephone sockets enable direct communication between firefighters and the central control panel during an emergency.
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
3. Control Layer (The "Brain" of the System)

The control layer is the central intelligence of the entire fire alarm system. Its main components are the Fire Alarm Control Panel (FACP) and the Gas Suppression Control Panel.

  • The FACP receives signals from all detectors and modules, decides when to generate alarms, and activates all connected field devices.
  • The Gas Suppression Control Panel is specially designed for FM200, IG541, CO₂, and other clean agent systems. It supports functions such as delay before release, manual/automatic mode selection, and pressure switch monitoring.
  • Additional control devices include repeater panels for displaying alarms on different floors and fire broadcast control panels for playing pre-recorded or live evacuation messages.
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
4. Execution Layer (Alarm and Action Equipment)

The execution layer carries out the commands issued by the control panel. It includes alarm sounder-strobes, output modules, fire alarm bells, and gas release indicators.

  • Alarm sounder-strobes produce high-audibility sounds and flashing lights to clearly alert occupants to evacuate.
  • Output modules control external equipment such as exhaust fans, fire dampers, power cut-off relays, and elevator recall units.
  • Fire alarm bells offer a cost-effective solution for conventional or smaller systems.
  • Gas release indicators are mounted at the entrance of each protected area. They illuminate when gas is about to be released or has already been discharged, providing a clear visual warning not to enter.
Product Advantages
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
J-SAP-JBF4121A-Ex Manual Fire Alarm Button
  1. Built-in microprocessor for stable performance.
  2. Adopts SMT surface mount technology, with high reliability and good consistency.
  3. Uses a dual-bus system without polarity requirements, ensuring low power consumption while enabling transmission distance to reach up to 1000 m.
  4. Explosion-proof type is intrinsically safe, requiring a safety barrier to be connected for use.
  5. Electronic coding method — can be addressed through a dedicated electronic encoder.
  6. Simple operation: pressing the operation panel on the panel realizes reporting a fire alarm to the controller.
  7. The operation panel of the manual alarm button needs to be reset after being pressed. This must be done using a dedicated key that matches the button.
  8. The manual alarm button adopts a plug-in structure, which is easy for customers to install, construct, and maintain.
Technical Parameters
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
Operating Environmental Conditions
Operating temperature -10 to +55°C
Storage temperature -30 to +75°C
Relative humidity ≤ 95% RH (40 ± 2°C)
Technical Specifications
Operating Voltage DC 18–28V, modulated type provided by controller (must use safety barrier)
Standby Current ≤ 0.3mA (24V)
Alarm Current ≤ 1mA (24V)
Explosion-proof Mark Ex ib IIC T6 Gb
Addressing Method Electronic encoder addressing
Addressing Range 1–200
Indicator Light Fire indicator flashes momentarily in standby mode; stays steady red when pressed and in alarm
Dimensions 90mm (L) × 90mm (W) × 52mm (H)
Wiring System Two-wire bus, non-polarity
Send your message to this supplier
Send Now

Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application

Ask Latest Price
Watch Video
Model Number :
J-SAP-JBF4121A
Temperature :
-10℃ to +55℃
MOQ :
100 set system
Delivery Time :
15-20days
Working Voltage :
DC19-28V
Light Intensity :
135cd
Contact Supplier
video
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application
Wall Mounting Battery Powered Manual Fire Alarm Button and Manual Call Point for Data Center Application

Guangzhou Xingjin Fire Equipment Co.,Ltd.

Verified Supplier
11 Years
guangdong, guangzhou
Since 2010
Business Type :
Manufacturer, Exporter
Total Annual :
600000-1200000
Employee Number :
100~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement