Specifications
Filling Pressure :
5.6/4.2 MPa
Discharge Time :
≤10s
Filling Density :
≤1250kg/m³
Drive Device Pressure :
6.0Mpa(20℃)
Pressure of Adding Pressure Cylinder :
13.5Mpa
Ambient Temperature :
0~50℃
Cylinder Volume :
90Ltr
Power :
DC24V/1A
Brand Name :
Xingjin
Model Number :
QMQ5.6/90W-XJ, QMQ5.6/120W-XJ, QMQ5.6/150W-XJ, QMQ5.6/180W-XJ, QMQ4.2/245W-XJ
Certification :
CAL,CMA,CNAS,ILAC-MRA,CCC
Place of Origin :
Guangdong
MOQ :
1 set
Price :
negotiation
Payment Terms :
L/C, D/P, T/T, Western Union, Paypal, Credit card
Supply Ability :
20000 sets per month
Delivery Time :
10-15 days
Packaging Details :
Plywood outer box with bubble bag or paper
Description
Product Overview

The FM-200 Piston Flow Clean Agent Fire Suppression System is designed to deliver FM-200 agent — a safe, environmentally friendly clean agent with a proven track record for helping protect people and high-value assets. This system introduces a new technology intended to extend the pipe length within the fire extinguishing system. It consists of an FM-200 container with agent and a supporting nitrogen container to enhance the discharge of the agent.

6.0Mpa Drive Device Pressure FM200 Piston Flow System with 90Ltr Cylinder Volume and DC24V/1A Power for Clean Agent Fire Suppression
Technical Specifications
No.NameSpecification
1Device ModelQMQ5.6/90W-XJ, QMQ5.6/120W-XJ, QMQ5.6/150W-XJ, QMQ5.6/180W-XJ, QMQ4.2/245W-XJ
2Cylinder Volume90 Ltr, 120 Ltr, 150 Ltr, 180 Ltr, 245 Ltr
3Filling Capacity of Gas112.5 kg, 150 kg, 187.5 kg, 225 kg, 306.25 kg
4Max Working Pressure8 MPa, 5.3 MPa
5Max Protected AreaSingle zone: 800 m²
6Max Protected VolumeSingle zone: 3600 m³
7Spraying Time≤ 10 s
8Agent Filling Density≤ 1250 kg/m³
9PowerDC 24V / 1A
10Pressure of Adding Pressure Cylinder13.5 MPa
11Pressure of Driving Device6.0 MPa (20 ℃)
12Condition of Reserving Room for ContainerTemperature: 0 ~ 50 ℃
System Composition

This system mainly consists of an agent storage cylinder, container valve, driving cylinder group, adding pressure cylinder group, distributing valve, liquid flow check valve, gas flow check valve, safety valve, pressure switch, frame, nozzle, high pressure hose, pressure-relief device, level gauge, relief valve, and pipe system. These components can constitute a unit independent system. Combined distribution systems and other forms can implement fire protection for single and multiple zones.

Pipe fittings are the conduits that connect the extinguishing device and guide the agent into the protective zone, such as high-pressure galvanized steel pipe, flange, and elbow.

Electrical accessories are used to detect and monitor the whole protective area, control the entire system, warn people to evacuate, and prevent fire expansion.

These three integrated parts work together efficiently to detect, supervise, alarm, and extinguish fire automatically.

6.0Mpa Drive Device Pressure FM200 Piston Flow System with 90Ltr Cylinder Volume and DC24V/1A Power for Clean Agent Fire Suppression
6.0Mpa Drive Device Pressure FM200 Piston Flow System with 90Ltr Cylinder Volume and DC24V/1A Power for Clean Agent Fire Suppression
Competitive Advantages
  • The FM-200 agent can be used for all kinds of class fires except metal fires. It is a clean agent, leaving no residue or pollution after extinguishing.
  • The FM-200 extinguishing system is specially suited for critical assets or devices, causing no damage to your property. It is a relatively cheap and effective choice as a fire suppression system.
  • Compared to traditional pipe network type fire suppression systems, it can push the agent farther within the effective fire-fighting time by relying on an external driving force.
Applications

It is widely used in computer rooms, power distribution rooms, telecommunications centers, libraries, archives, treasure chests, and underground engineering for Class A, B, and C fires and electrical equipment fires.

Not applicable to places involving potassium, sodium, magnesium, uranium, active metal chlorides, or digestive fiber fires.

Packaging

Products are always packed with polyfoam first and then placed into a wooden case. When required to meet customer or safety requirements, goods can also be palletized.

6.0Mpa Drive Device Pressure FM200 Piston Flow System with 90Ltr Cylinder Volume and DC24V/1A Power for Clean Agent Fire Suppression
Company Introduction

Guangzhou Xingjin Fire Equipment Co., Ltd. is located in Guangzhou, surrounded by convenient transportation and a beautiful environment, and plays an important role in communication between China and the world. As a manufacturer, we devote ourselves to the study and development of HFC-227ea (FM200) products with a professional and mature team that includes a program design team, a skillful installation team, a quality detecting team, and an after-sales service team.

Today, our popular FM200 products are widely used, including the pipe network FM200 fire suppression system, the cabinet type FM200 fire suppression system, the automatic FM200 fire extinguisher (ceiling-mounted style), the fire detecting tube suppression system, and the automatic fire suppression tube. As a result of high-quality products and services as well as a good reputation, our company is well received by customers in China.

Why Choose Us
  • 5-year quality guarantee.
  • Xingjin operates under a high-efficiency management system.
  • Advanced equipment and professional engineers ensure all products are highly satisfactory.
  • 8 × 6 hours of technical support and service.
After-Sales Service
  • An efficient sales and after-sales team ensures all client questions are resolved in a timely manner.
  • 8 × 6 hours of technical support and service.
FAQ

Q: Are you a manufacturer or a trading company?

A: We are a manufacturer.

Q: Is the OEM order available?

A: Yes, we produce in accordance with each client's requirements.

Q: Where is your factory located, and how can I visit there?

A: Our factory is located in Guangzhou, Guangdong Province, China. You are very welcome to visit our factory.

Send your message to this supplier
Send Now

6.0Mpa Drive Device Pressure FM200 Piston Flow System with 90Ltr Cylinder Volume and DC24V/1A Power for Clean Agent Fire Suppression

Ask Latest Price
Watch Video
Filling Pressure :
5.6/4.2 MPa
Discharge Time :
≤10s
Filling Density :
≤1250kg/m³
Drive Device Pressure :
6.0Mpa(20℃)
Pressure of Adding Pressure Cylinder :
13.5Mpa
Ambient Temperature :
0~50℃
Contact Supplier
video
6.0Mpa Drive Device Pressure FM200 Piston Flow System with 90Ltr Cylinder Volume and DC24V/1A Power for Clean Agent Fire Suppression

Guangzhou Xingjin Fire Equipment Co.,Ltd.

Verified Supplier
11 Years
guangdong, guangzhou
Since 2010
Business Type :
Manufacturer, Exporter
Total Annual :
600000-1200000
Employee Number :
100~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement