Specifications
Brand Name :
xingjin
Model Number :
GQQ40/2.5, GQQ70/2.5, GQQ90/2.5, GQQ100/2.5, GQQ120/2.5, GQQ150/2.5, GQQ180/2.5
Certification :
CAL,CMA,CNAS,ILAC-MRA,CCC
Place of Origin :
China
MOQ :
1set system
Price :
negotiation
Payment Terms :
L/C, T/T, D/P, Western Union,Paypal,Credit Card,Debit Card
Supply Ability :
300 sets per month
Delivery Time :
10-15 working days after payment or receipt of L/C
Packaging Details :
Plywood case,Paper carton
Spraying time :
≤10s
Actuation :
Automatic or manual
Pattern Of Extinguishing :
Enclosed Flooding
printed color :
silver(cabinet), red(cylinder)
Working pressure :
2.5MPa
Capacity of Gas :
38kg, 66.5kg, 85.5kg, 95kg, 114kg, 142.5kg, 171kg
Description
100L FM200 Cabinet Extinguisher — Single Cylinder with Two Nozzles

Swiftness, efficiency, and tenacity in extinguishing fire.

In less than 10 seconds, the FM200 pure gas automatic fire extinguishing system can completely put out a fire. The clean gas extinguishing agent FM200 normally has a low concentration — only 9% — when measured according to the reserve design extinguishing concentration. FM200 clean extinguishing agent is a liquid that can be stored and is immediately transformed into a gas that is highly driven to put out fires.

The FM200 clean gas automated fire extinguishing system is ideal for safeguarding documents, high-value equipment, electrical and magnetic media, as well as collections and archives. Protected items are not harmed, no residue is left after a fire, and the normal operations of the protected areas are not obstructed.

No Residue FM200 Cabinet System and FM200 Cabinet Extinguisher with Enclosed Flooding and Automatic or Manual Actuation
System Composition

An extinguishing mechanism and electrical components make up the entirety of a one-set system (the composition is shown in the illustration below).

One set of the cabinet-type FM200 fire suppression equipment consists of FM200 agent, an FM200 cylinder, a hoop, a cabinet, a container valve, a solenoid actuator, a flexible hose (high-pressure hose), nozzle(s), and a pressure switch.

No Residue FM200 Cabinet System and FM200 Cabinet Extinguisher with Enclosed Flooding and Automatic or Manual Actuation
Applications
  • Clean rooms, anechoic chambers, emergency power facilities, and flammable liquid storage spaces
  • Data processing centers, telecommunications facilities, and process control rooms
  • High-value medical equipment, industrial equipment, libraries, museums, and art galleries
  • Areas where fires are more likely to occur — engine rooms, cargo holds, rolling mills, printing presses, oil switches, oil-immersed transformers, and paint-spraying production lines
No Residue FM200 Cabinet System and FM200 Cabinet Extinguisher with Enclosed Flooding and Automatic or Manual Actuation
Technical Parameters
No. Specifications Parameters
1 Cylinder capacity 40L, 70L, 90L, 100L, 120L, 150L, 180L
2 Device model GQQ40/2.5, GQQ70/2.5, GQQ90/2.5, GQQ100/2.5, GQQ120/2.5, GQQ150/2.5, GQQ180/2.5
3 Filling pressure 2.5 MPa
4 Max filling rate 0.95 kg/L
5 Discharge time ≤ 10 s
6 Working temperature 0 ℃ ~ 50 ℃
7 Max working pressure 4.2 MPa
8 Discharge pressure 5.6 ± 0.28 MPa
9 Proportion of protected zone ≤ 500 m²
10 Volume of protected zone ≤ 1600 m³
11 Actuation Automatic or manual start
Competitive Advantages

There are several benefits to using a cabinet fire suppression system. The following is a brief explanation of some of them:

  1. Quick reaction. FM200 gas can be released directly into the protection zone because there is no need for long-distance pipe transmission. Its spraying cycle lasts less than 8 seconds, so overall response time is shorter when a fire occurs.
  2. Easy installation. Comparatively speaking, installing a cabinet system is easier than a pipe network system. After installing control panels and electrical components, the only remaining task is connecting them to one or more cabinet fire extinguishing systems. However, due to the control panel's output current limitation, no more than 4 units should be placed in a single room.
  3. Lower price. For a protective zone that only requires a single cylinder, the cost is undoubtedly lower than for a pipe network type, since there is no need to factor in the cost of pipes, pipe fittings, or labor for this component.
After-Sale Service

  • We pledge to promptly address all client questions thanks to our effective sales and after-sales teams.
  • We offer technical support and service 8–6 hours a day.
Send your message to this supplier
Send Now

No Residue FM200 Cabinet System and FM200 Cabinet Extinguisher with Enclosed Flooding and Automatic or Manual Actuation

Ask Latest Price
Watch Video
Brand Name :
xingjin
Model Number :
GQQ40/2.5, GQQ70/2.5, GQQ90/2.5, GQQ100/2.5, GQQ120/2.5, GQQ150/2.5, GQQ180/2.5
Certification :
CAL,CMA,CNAS,ILAC-MRA,CCC
Place of Origin :
China
MOQ :
1set system
Price :
negotiation
Contact Supplier
video
No Residue FM200 Cabinet System and FM200 Cabinet Extinguisher with Enclosed Flooding and Automatic or Manual Actuation

Guangzhou Xingjin Fire Equipment Co.,Ltd.

Verified Supplier
11 Years
guangdong, guangzhou
Since 2010
Business Type :
Manufacturer, Exporter
Total Annual :
600000-1200000
Employee Number :
100~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement