Specifications
Brand Name :
Kacise
Model Number :
KOCF3000
Place of Origin :
China
MOQ :
1
Price :
280USD/pc
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
100+
Delivery Time :
5-8 work days
Packaging Details :
carton
Measurement range :
0.1L/s~99999.99m3/h
Total flow :
Max.: 4290000000.00m3
Max. scale value of water level :
3m, 0.40m for dead area
Measurement accuracy of water level :
0.5%
Resolution ratio :
3mm or 0.1% (the larger one shall be taken)
Display :
LCD
Flow measurement accuracy :
1~5% for standard weir flume (wire flume and channel complied with national standards); 10~50% for non-standard weir flume
Communication :
Optional, 485 & 232 communication, MODBUS protocol
Process pressure :
Standard atmospheric pressure
Process temperature :
-20~+80℃
Working pressure :
Standard atmospheric pressure
Power supply :
Standard 24VDC 100mA; or optional 220V AC+15% 50Hz
Description

KOCF3000 Series Ultrasonic Open Channel Flow Meter

Instruction
The KOCF3000 series ultrasonic open channel flow meter,together with measuring weir flume, is used to measure water
flow in open channel. It is mainly used to measure the flow of sewage plant, sewage discharge outlet of enterprises and public
institutions, urban sewers, as well as the channels for irrigation and water conservancy.

Feature
As for the meters produced by KACISE, the non-contact method is used for measurement by letting ultrasonic wave passing through air. Therefore, they are more reliable and durable in dirty and corrosive solutions compared with the contact-type meters.

Parameters

Functions Integrated type Split type
Measurement range 0.1L/s~99999.99m3/h
Total flow Max.: 4290000000.00m3
Max. scale value of water level 3m, 0.40m for dead area
Measurement accuracy of water level 0.5%
Resolution ratio 3mm or 0.1% (the larger one shall be taken)
Display LCD display
Flow measurement accuracy 1~5% for standard weir flume (wire flume and channel complied with national standards); 10~50% for non-standard weir flume
Analog output 4-wire, load of 4~20mA/600Ω
Relay output (Optional) 2 sets AC 220V/ 8A or DC 24V/ 5A
Power supply Standard 24VDC 100mA; or optional 220V AC+15% 50Hz
Power supply (Optional) 12VDC, supplied by battery or solar energy
Working temperature display instrument -20~+60°C, probe -20~+80°C
Working pressure Standard atmospheric pressure
Working temperature ≤90%RH, non-condensed
Process temperature -20~+80℃;
Process pressure Standard atmospheric pressure
Communication Optional, 485 & 232 communication, MODBUS protocol
IP grade Meter IP66, probe IP68 Meter IP66, probe IP68
Probe cable None Standard 10m, max. 100m
Probe installation size M78×2 thread is the first chose, with small transmitting angle and small blind area of 20cm. G1-1/2 thread + matting thread, and M48×2 thread + matting thread are optional, with blind area of 30-40cm.
Probe material Standard made by ABS, and anticorrosive material shall be used for ones for the corrosive environment
Power dissipation of split type

The split type is provided with 24V power, with power dissipation of 100mA for ones without relay, 120mA for ones with one relay, 145mA for ones with two relays, 170mA for ones with three relays, and 190mA for ones with four relays. The specific power is as below:

Product without relay: 24×100mA=2.4W;

Product with one relay: 24×120mA=2.9W; Product with two relays: 24×145mA=3.5W

Product with three relays: 24×170mA=4.1W; Product with four relays: 24×190mA=4.6W;

Power dissipation of integrated type

The integrated four-circuit type is provided with 24V power, with power dissipation of 80mA for ones without relay, 105mA for ones with one relay, 105mA for ones with two relays. The specific power is as below:

Product without relay: 24×80mA=1.9W;

Product with one relay: 24×105mA=2.5W; Product with two relays: 24×145mA=3.1W

Dimensions

KOCF3000 Ultrasonic Open Channel Flow Meter For River / Canal

Note: The display instrument of split-type ultrasonic open channel flow meter shall be installed indoor with good ventilation condition and free from corrosive gas. The instrument shall be hanged on the wall. If it must be installed outdoor due to poor indoor condition, the instrument shall be packed in a protective box and kept free from sunlight and rain.

Send your message to this supplier
Send Now

KOCF3000 Ultrasonic Open Channel Flow Meter For River / Canal

Ask Latest Price
Brand Name :
Kacise
Model Number :
KOCF3000
Place of Origin :
China
MOQ :
1
Price :
280USD/pc
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Supplier
KOCF3000 Ultrasonic Open Channel Flow Meter For River / Canal
KOCF3000 Ultrasonic Open Channel Flow Meter For River / Canal
KOCF3000 Ultrasonic Open Channel Flow Meter For River / Canal