MPO OM3 OM4 PVC LSZH fiber optic patch cord
Technical Parameters
| Parameter | unit | Numerical value | ||||
| Connector type | / | MPO-MPO,MTP-MTP | ||||
| Central wavelength | nm | 1550 | 1310 | 1300 | 850 | |
| Maximum insertion loss (23℃) | dB | Typical value 0.3 maximum 0.75 | Typical value 0.3 maximum 0.75 | Typical value 0.3 maximum 0.75 | Typical value 0.3 maximum 0.75 | |
| Minimum return loss (23℃) | PC | dB | ≥45 | ≥20 | ||
| UPC | dB | ≥50 | ≥25 | |||
| APC | dB | ≥60 | ≥45 | |||
| Repeatability | dB | ≤0.1 | ||||
| Interchangeability | dB | ≤0.2 | ||||
| Axis alignment Angle tolerance | deg | ±0.3 | ||||
| Nuber of plug | times | ≥500 | ||||
| Operating temperature | ℃ | -20~+70 | ||||
| Storage temperature | ℃ | -40~+85 | ||||
| Central wavelength | 1550nm,1310nm, 1300nm,850nm |
| Enter the connector type Out-put connector type | MPO/UPC(M),MPO/UPC(F),MTP/UPC(M),MTP/UPC(F) MPO/APC(M),MPO/APC(F),MTP/APC(M),MTP/APC(F) |
| MPO/UPC(M),MPO/UPC(F),MTP/UPC(M),MTP/UPC(F) | |
| MPO/APC(M),MPO/APC(F),MTP/APC(M),MTP/APC(F) | |
| Optical fiber number | 8=8 Fiber, 12=12 Fiber, 16=16 Fiber, 24=24 Fiber, or specified |
| Optical fiber type | G652D,G657A1,G657A2,OS2,OM1,OM2,OM3,OM4,OM5,or specified |
| Fiber diameter | Φ9/125um,Φ50/125um,Φ62.5/125m |
| Cable outer diameter | Φ3.0mm,Φ3.5mm,Φ4.5mm,or specified |
| Product line sequence The pigtail pigtail | A polarity, B polarity, C polarity MPO/UPC(M),MPO/UPC(F),MTP/UPC(M),MTP/UPC(F) |
| MPO/APC(M),MPO/APC(F),MTP/APC(M),MTP/APC(F) |