I-suntop wire and cable Testing machine20220301.pd...
Meet the standards: BSI, UL, VDE, CSA, SAA, T-MARK, KS, IRAM, CCC and other national standards
Scope of application: Detecting the polarity conduction, insulation, core high voltage and copper leakage of the power cord cable
| SPECIFICATIONS FOR Power cord plug cable tester | |
| Technical Index | Tech-Parameters |
| Polarity | Break over, short circuit, open circuit, dislocation |
| Leakage current | Setting Range:0.5, 1.0, 2.0, 3.0, 5.0, 10mA |
| Internal High-Voltage | Output 0---5KV(500VA) Adjustable |
| External High-Voltage | Output 0---5KV(500VA) Adjustable |
| Operating Voltage | 220VAC 12A 5060 HZ |
| Voltmeter High-voltage | range:0-5KV |
| Resolution | 0.5 level |
| Insulation Voltage | Output Voltage:DC500V |
| Insulation resistance | Range:2,7,20,50,100,200MΩ |
| Voltage withstand time | Timing Range:0.1-99.9/S |
| Min time for item | measuring:0.3S |
| Wire sensitivity | >10pF |
| Barometric Pressure | <4 Kgf/cm2 |
| OK Product | Automatic printing and push out, counting, and indicator ON |
| NG Product | Automatic model locking, counting,indictor ON and buzzer ringing |
| Safeguard | electric leakage, Short circuit ,overheating |
| Size | (W)730*(D)530*(H)500 (mm), |
| Machine Weight | 68Kg |