The DC EFU 1170X1170X110+35 redefines precision air filtration for hyperscale data centers, server farms, and edge computing facilities, combining a patented modular design with direct current (DC) ultra-high efficiency. Featuring a two-tier 110+35mm stackable chassis, this EFU delivers 2200 CMH airflow at just 42dB(A) while achieving HEPA efficiency for ISO Class 3-5 environments. Its IoT-enabled predictive maintenance and hot-swappable filter trays ensure zero downtime in 24/7 critical operations, compliant with ASHRAE TC9.9 and TIA-942 standards.
| Parameter Name | Value |
|---|---|
| Material | High-quality aluminum-zinc plate |
| Fan System | EBM DC 470 motor |
| Air Speed | 0.45-0.75 m/s ±5% (group control) |
| Noise Level | 48-58 dB ±5dB (static test 1m below filter) |
| Power Supply | 220V, 50Hz |
| Size | 1170X1170X110+35(mm) |
| Certifications | ISO 14644-1, ISO 9001, CE |
| Parameter/Feature | Our Product | Market Average | Advantages |
|---|---|---|---|
| Filter Pleat Count | 315 pleats | 260 pleats | Larger filtration area, improving filtration efficiency and dust holding capacity |
| HEPA Filter | - | - | Increased thickness of filtration media enhances filtration effectiveness and lifespan |
| Pleat Height | 50 mm | 38 mm | Thicker filtration media improves filtration performance and longevity |
| Protective Mesh Brand | High-quality 9N brand | Generic brands | Superior support and protection, ensuring structural stability |
| Frame Thickness | 1.0 mm | 0.7 mm | Stronger frame for enhanced durability and reduced deformation risks |
| Potting Process & Materials | 50 units per batch, Fuming AB adhesive, produced with CNY 400k potting machines | Standard processes | Tight, uniform sealing prevents leaks and guarantees reliable filtration |
| Average Airflow Velocity | 0.8 m/s | 0.65 m/s | Higher airflow capacity with lower resistance, boosting system efficiency |
| Motor | Waterproof | Non-waterproof | Enhanced safety and reliability in diverse environments |
A: Our 48V DC system eliminates AC/DC conversion losses, reducing power consumption by 18-22% per rack. Integrated with lithium-ion UPS backups, it maintains airflow during grid fluctuations--critical for Tier IV data centers requiring uptime.
A: Yes, the dual-height chassis allows: 35mm slim units for retrofitting existing 19" racks; 110mm full-capacity units for new high-density deployments; Mixed configurations via tool-free magnetic coupling.
A: Embedded sensors monitor: Real-time server heat loads (via thermal imaging); Particulate levels; Filter pressure drop (auto-alerts at 90% capacity). The system dynamically redistributes airflow within ±2% variance, preventing hot spots.