Specifications
Brand Name :
FeiChun™
Model Number :
MGCH-FFR Fire-Resistant and Shielded Marine Cable
Certification :
VDE 0250 Part 813
Place of Origin :
Hefei Anhui China
MOQ :
200 Meter
Price :
10-50 USD per meter, price varies according to specifications
Payment Terms :
T/T, Western Union
Supply Ability :
16,000 meters per week
Delivery Time :
15-30 Work Day
Packaging Details :
Cable Reels or Packaging Bags
Conductor Integrity :
Reliable Conductor Integrity
Outstanding Durability :
Durable And Reliable
Maximum Ampacity :
170 Amps
Halogen Free :
IEC 60754-1, IEC 60754-2, IEC 61034-1, IEC 61034-2
Weather Resistance :
Resilient In Diverse Weather
Features :
Flexible, Oil and Sunlight Resistant
Sturdy Connector Design :
Solid Connector Construction
Current Rating :
1000A
Safety Certifications :
Certified For Safety
High Current Capability :
Efficient High-current Transmission
Easy Installation Process :
Easy To Install
Resistance :
Oil, Chemicals, Abrasion
Certifications :
MSHA, CSA, UL
Compact Installation :
Compact Design
Description

Enhanced Fire Safety and EMI Protection: A Comprehensive Guide to Feichun Type MGCH-FFR Fire-Resistant and Shielded Marine Cables

I. Introduction: Combining Fire Resistance and EMI Shielding

In marine environments, where safety and reliability are paramount, the choice of cabling can make all the difference. Feichun Cable, a leader in specialized cable manufacturing, offers the Type MGCH-FFR, a cutting-edge solution designed to meet the unique challenges faced in marine applications.

Enhanced Fire Safety and EMI Protection: A Comprehensive Guide to Feichun Type MGCH-FFR Fire-Resistant and Shielded Marine Cables

The Type MGCH-FFR cable is specially engineered for fixed installations in electromechanical and electronic equipment aboard marine vehicles. It ensures sustainable connections during fires and minimizes electromagnetic interference (EMI) to protect sensitive onboard equipment.

With dual features of fire resistance per IEC 60331 and robust EMI shielding, this cable is the ideal choice for critical marine operations.

This article dives into the technical construction, key specifications, applications, and installation practices of the Type MGCH-FFR cable, helping you understand how it provides exceptional fire safety, circuit integrity, and EMI protection.


II. Technical Specifications and Standards Compliance

Sub-headline: Meeting Demanding Requirements

The Type MGCH-FFR complies with stringent international standards, ensuring top-notch performance in even the harshest marine conditions. Below is a detailed breakdown of its construction, materials, and compliance:

Parameter Details
Construction Standard DIN 89158, IEC 60092/353
Testing Standards IEC 60092 /350-351-359
Rated Voltage 0.6/1 kV
Test Voltage 3.5 kV
Temperature Range -40°C to +90°C
Flame Retardancy IEC 60332/1 (single cable) and IEC 60332/3 Cat A (bunched cables)
Fire Resistance IEC 60331: Ensures circuit integrity during fire
Halogen-Free Properties IEC 60754/1–2: Reduces toxic fumes and smoke during a fire
Smoke Density IEC 61034/1–2 (DIN EN 50268/1–2): Ensures low smoke emission
UV Resistance EN 50289-4-17 A&B, ISO 4892-2&3: Protects against sunlight degradation

1. Conductor

  • Material: Electrolytic, stranded, annealed copper wire compliant with IEC 60228 Class 2 (rigid) or Class 5 (flexible). Tinned copper is available on request.

  • Advantages:
    • Class 2 conductors offer higher mechanical strength for fixed installations.
    • Class 5 conductors provide excellent flexibility for dynamic systems.
    • Tinned copper resists corrosion and improves conductivity in high-salt environments.


2. Separator

  • Material: Mica tape, known for its natural fire-resistant properties, protects conductors even under high heat.
    • Function: Prevents short circuits by maintaining insulation integrity during fires.


Enhanced Fire Safety and EMI Protection: A Comprehensive Guide to Feichun Type MGCH-FFR Fire-Resistant and Shielded Marine Cables

3. Insulation

  • Material: HF HEPR (Halogen-Free Heat Resistant Ethylene Propylene Rubber).

  • Key Benefits:
    • Excellent electrical properties.
    • High flexibility, especially in low temperatures.
    • Resistance to ozone, chemicals, and weathering.


4. Bedding Layer

  • Material: Halogen-free compound.

  • Function: Protects inner components and provides a smooth surface for the screen.


5. Screen

  • Material: Electrolytic copper braid with 90% coverage.

  • Function: Shields against EMI, protecting sensitive systems from interference.


6. Outer Sheath

  • Material: Halogen-free, flame-retardant, UV-resistant thermoplastic polyolefin compound (SHF1).

  • Properties:
    • Halogen-free: Reduces toxic emissions during fire.
    • UV and sunlight resistant: Withstands prolonged exposure to marine conditions.
    • Flame-retardant and fire-resistant: Ensures compliance with IEC 60331 for circuit integrity.
    • Green Color: Signifies fire-resistant circuits for easy identification.

III. Installation Guidelines and Best Practices

Sub-headline: Maintaining Fire Resistance and Shielding Effectiveness

Proper installation is critical for ensuring the Type MGCH-FFR's performance. Follow these best practices:

1. Cable Handling

  • Avoid excessive bending or pulling to prevent damage to the mica tape and screen.

  • Inspect the cable for visible damage before installation.


2. Cable Routing

  • Keep cables away from high-temperature zones and potential EMI sources.

  • Use fire-resistant supports and penetrations to maintain fire compartmentation.


3. Termination and Connection

  • Use fire-resistant glands and connectors to preserve integrity during fires.

  • Ground the copper screen correctly for effective EMI shielding.


4. Bending Radius

  • Adhere to the minimum bending radius of 8 x Overall Diameter to avoid compromising the insulation or screen.


Enhanced Fire Safety and EMI Protection: A Comprehensive Guide to Feichun Type MGCH-FFR Fire-Resistant and Shielded Marine Cables

IV. Common Challenges and Troubleshooting

Sub-headline: Ensuring Reliable Performance

Issue Cause Impact Solution
Damage to Mica Tape Excessive bending or mechanical stress Reduced fire resistance Handle carefully; maintain correct bending radius.
Screen Damage Improper handling Reduced EMI shielding Avoid pulling or twisting during installation.
Improper Terminations Incorrect techniques Connection failures, reduced shielding Follow manufacturer guidelines for termination.
Inadequate Grounding Poor screen bonding Increased interference Ensure proper grounding and bonding.

V. Conclusion

Sub-headline: Enhanced Safety and Reliability for Critical Marine Systems

The Feichun Type MGCH-FFR stands out for its fire resistance, EMI protection, and halogen-free properties, making it an indispensable asset for marine vehicles. Its robust design, compliance with stringent standards, and superior materials ensure long-lasting performance in challenging environments.

To ensure optimal performance, follow proper installation and handling guidelines. For more information, technical support, or to request a quote, contact Feichun Cable today.


VI. Appendices

Glossary

  • Mica Tape: A fire-resistant material used for insulation.

  • HEPR: A halogen-free, heat-resistant rubber compound.

  • EMI: Electromagnetic interference, which disrupts electronic signals.

Technical Data Sheet

Parameter Value
Conductor Stranded, tinned copper
Voltage Rating 0.6/1 kV
Fire Resistance Standard IEC 60331

Make safety and reliability your top priorities with Feichun Type MGCH-FFR, the cable solution designed for critical marine applications.

Enhanced Fire Safety and EMI Protection: A Comprehensive Guide to Feichun Type MGCH-FFR Fire-Resistant and Shielded Marine Cables Enhanced Fire Safety and EMI Protection: A Comprehensive Guide to Feichun Type MGCH-FFR Fire-Resistant and Shielded Marine Cables Enhanced Fire Safety and EMI Protection: A Comprehensive Guide to Feichun Type MGCH-FFR Fire-Resistant and Shielded Marine Cables

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Send your message to this supplier
Send Now

Enhanced Fire Safety and EMI Protection: A Comprehensive Guide to Feichun Type MGCH-FFR Fire-Resistant and Shielded Marine Cables

Ask Latest Price
Brand Name :
FeiChun™
Model Number :
MGCH-FFR Fire-Resistant and Shielded Marine Cable
Certification :
VDE 0250 Part 813
Place of Origin :
Hefei Anhui China
MOQ :
200 Meter
Price :
10-50 USD per meter, price varies according to specifications
Contact Supplier
Enhanced Fire Safety and EMI Protection: A Comprehensive Guide to Feichun Type MGCH-FFR Fire-Resistant and Shielded Marine Cables

Anhui Feichun Special Cable Co., Ltd

Active Member
2 Years
anhui, hefei
Since 2006
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter, Seller
Total Annual :
300K-500K
Employee Number :
200~230
Certification Level :
Active Member
Contact Supplier
Submit Requirement