Specifications
Brand Name :
Sinuo
Model Number :
SN2210-35
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Price :
Negotiation
Payment Terms :
T/T
Supply Ability :
100 pcs/month
Delivery Time :
3 days
Packaging Details :
Aluminium box and carton box
Applied Standard :
UL 2594
Applied Clause :
Clause 8.2
Applied Figure :
Figure 6
Probe Feature :
Joint probe
Test Sample :
Live/mechanical parts
Probe Material :
Nylon and metal
Test Function :
Enclosure Protection
Package type :
Aluminium box
Description

UL 2594 Clause 8.2 Figure 6 Articulate Probe

Equipment Overview for UL 2594 Clause 8.2 Figure 6 Articulate Probe


Standard:UL 2594 clause 8.2 figure 6.

Application:It is widely used in the enclosure protection test of the electrical equipment.

Test sample: Easily accessible enclosure live parts or mechanical parts.

Feature: Nylon handle + probe, it is manufactured according to the standard figure.

Technical Parameters for UL 2594 Clause 8.2 Figure 6 Articulate Probe


Probe material Stainless steel
Handle material Nylon
Applied force Without built-in force, should work with a force gauge
Applied standards UL 2594 Clause 8.2 Figure 6

Description of Relevant Standards for UL 2594 Clause 8.2 Figure 6 Articulate Probe


8 Protection of Users- Accessibility and User Servicing


8.1 General


8.1.1 The requirements in this section apply to parts that are accessible to the user. For protection of servicepersonne requirements, refer to Protection of Service Personnel, 32.

8.2 Accessibility


8.2.1 To reduce the risk of unintentional contact that results in electric shock from an uninsulated live part or film-coated wire, an opening in an enclosure shall comply with either:


a)For anopeningthat has a minor dimension less than 25.4 mm (1 inch). such a part or wire shall not be contacted by the probe illustrated in Figure 6.or


b)Foran opening that has a minor dimension of 25.4 mm (1 inch) or more, such a part or wire shall be spaced from the opening as specified in Table 8.

Table 8

Minimum required distance from an opening to a part that involves a risk of electric shock
Minor dimension of opening a, b Minimum distance from opening to part b
mm inches mm inches
25.4 (1) 165.0 (6-1/2)
31.8 (1-1/4) 190.0 (7-1/2)
38.1 (1-1/2) 318.0 (12-1/2)
47.6 (1-7/8) 394.0 (15-1/2)
54.0 (2-1/8) 444.0 (17-1/2)
c 762.0 (30)

a See 8.2.4

b Between 19.1 and 54 mm (3/4 and 2-1/8 inches), interpolation is to be used to determine a value between values specified in the table.

c More than 54 mm (2-1/8 inches), and not more than 152.0 mm (6 inches).

Pictures for UL 2594 Clause 8.2 Figure 6 Articulate Probe


UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material

UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material

Send your message to this supplier
Send Now

UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material

Ask Latest Price
Watch Video
Brand Name :
Sinuo
Model Number :
SN2210-35
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Price :
Negotiation
Contact Supplier
video
UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material
UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material
UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material
UL 2594 Clause 8.2 Figure 6 Articulated Probe Nylon And Metal Material

Sinuo Testing Equipment Co. , Limited

Verified Supplier
4 Years
guangdong, guangzhou
Since 2019
Business Type :
Manufacturer
Employee Number :
<100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement