Specifications
Model Number :
TF-30D201 (TF-30 Sensor + DTF-201 Receiver)
Analog Output :
Air-point plus up to three-point calibration Air one-point calibration Calibration via data input (during sensor replacement) Analog Output;DC 4–20 mA, non-isolated output, load resistance ≤600 Ω DC 0–1 V / DC 0–5 V / DC 0–10 V, selectable (non-isolated ou
Contact Output :
Open collector output, DC 25 V max. 50 mA Number of contacts: 4 outputs Selectable functions: Analyzer fault / Range echo-back 1 / Range echo-back 2 / Range echo-back 3 / Ready / High concentration alarm / Low concentration alarm
MOQ :
NO MOQ
Delivery Time :
Inquire
Calibration :
Air-point plus up to three-point calibration Air one-point calibration Calibration via data input (during sensor replacement)
Range Switching :
Local range switching / Remote range switching / Auto range switching
Sensor element: :
Zirconium dioxide pipe
Output Hold Function :
Output hold value setting: No hold* / User-defined value / Value 5 seconds before fault occurrence *Output held during warm-up and analyzer fault
Certification :
CE,RoHS
High/Low Concentration Alarm :
High alarm: Configurable from 0.0–9,990.0 ppm or 0.0–100.0% Low alarm: Configurable from 0.0–9,990.0 ppm or 0.0–100.0%
Packaging Details :
Common Package or Personalized Customization Package
Payment Terms :
L/C,D/A,D/P,T/T
Measuring Principle :
Zirconia type limiting current method
Measuring range: :
Min. 0–1,000 ppm to Max. 0–25%; Any four ranges selectable with fixed zero point *Output range configurable from 0–10 ppm to 0–100%
Accuracy :
±1% FS;±2% FS
RS-232C Communication Function :
Transmits measurement status, error code, measurement range, and measured value Communication cable specification: D-sub 9-pin, straight cable
Brand Name :
EVOzuRun
Sample & Calibration Gas Flow Rate :
0.5 L/min
Place of Origin :
China guangdong
Response Time :
≤60 seconds (below 0–1,000 ppm), ≤30 seconds (0–1,000 ppm and above) (90% response when switching calibration gas)
Price :
Inquire
OE NO. :
TF-30D201 (TF-30 Sensor + DTF-201 Receiver)
Power Supply :
AC specification: AC 100–240 V ±10%, 50/60 Hz, 50 VA ;DC specification: DC 24 V ±10%, 50 W
Contact Input :
Range switching (voltage-free contact)
Supply Ability :
Inquire
Applications :
Reflow furnaces Ferrite firing furnaces Other atmosphere management and combustion control applications
Drift :
≤±2% FS per week
Description

Features

  • Sensors and receiver can be installed at desired locations
  • Lightweight and compact design allows easy integration into various systems
  • No standard gas or reference air required (Calibration can be performed using air-point calibration)
  • Supports low-concentration measurement (minimum range: 0–1,000 ppm)
Send your message to this supplier
Send Now

Industrial Oxygen Gas Analyzer Sensor TF-30 Sensor for Reflow Furnaces Ferrite Firing Furnaces Other atmosphere management combustion control applicationsMarine Inert Gas System Control

Ask Latest Price
Model Number :
TF-30D201 (TF-30 Sensor + DTF-201 Receiver)
Analog Output :
Air-point plus up to three-point calibration Air one-point calibration Calibration via data input (during sensor replacement) Analog Output;DC 4–20 mA, non-isolated output, load resistance ≤600 Ω DC 0–1 V / DC 0–5 V / DC 0–10 V, selectable (non-isolated ou
Contact Output :
Open collector output, DC 25 V max. 50 mA Number of contacts: 4 outputs Selectable functions: Analyzer fault / Range echo-back 1 / Range echo-back 2 / Range echo-back 3 / Ready / High concentration alarm / Low concentration alarm
MOQ :
NO MOQ
Delivery Time :
Inquire
Calibration :
Air-point plus up to three-point calibration Air one-point calibration Calibration via data input (during sensor replacement)
Contact Supplier
Industrial Oxygen Gas Analyzer Sensor TF-30 Sensor for Reflow Furnaces Ferrite Firing Furnaces Other atmosphere management combustion control applicationsMarine Inert Gas System Control
Industrial Oxygen Gas Analyzer Sensor TF-30 Sensor for Reflow Furnaces Ferrite Firing Furnaces Other atmosphere management combustion control applicationsMarine Inert Gas System Control
Industrial Oxygen Gas Analyzer Sensor TF-30 Sensor for Reflow Furnaces Ferrite Firing Furnaces Other atmosphere management combustion control applicationsMarine Inert Gas System Control
Industrial Oxygen Gas Analyzer Sensor TF-30 Sensor for Reflow Furnaces Ferrite Firing Furnaces Other atmosphere management combustion control applicationsMarine Inert Gas System Control
Industrial Oxygen Gas Analyzer Sensor TF-30 Sensor for Reflow Furnaces Ferrite Firing Furnaces Other atmosphere management combustion control applicationsMarine Inert Gas System Control
Industrial Oxygen Gas Analyzer Sensor TF-30 Sensor for Reflow Furnaces Ferrite Firing Furnaces Other atmosphere management combustion control applicationsMarine Inert Gas System Control

Guangzhou Zhuyou Auto Parts Co., Ltd.

Verified Supplier
1 Years
guangdong, guangzhou
Since 2012
Business Type :
Manufacturer, Distributor/Wholesaler, Seller
Total Annual :
500000-1000000
Employee Number :
150~200