|   			 TECHNICAL SPRCIFICATIONS  |   		||||
|   			 Model  |   			  			 SFT-824  |   			  			 SFT-834  |   		||
|   			 Number of diodes  |   			  			 17  |   			  			 32  |   		||
|   			 Distance between diodes  |   			  			 118mm  |   			  			 59mm  |   		||
|   			 Maximum beams (distance≥400mm)  |   			  			 96beams  |   			  			 154beams  |   		||
|   			 Minimum beams (distance<400mm)  |   			  			 33beams  |   			  			 94beams  |   		||
|   			 Highest beam  |   			  			 1840mm  |   		|||
|   			 Lowest beam  |   			  			 23mm  |   		|||
|   			 Size  |   			  			 14mm(thickness)x18.6mm(width)x2000(height)  |   		|||
|   			 Detecting distance  |   			  			 0-4000mm  |   		|||
|   			 Vertical displacement at 0mm  |   			  			 ±20mm  |   		|||
|   			 Horizontal displacement at 0mm  |   			  			 ±3mm  |   		|||
|   			 Angular displacement at 0mm  |   			  			 ±10degrees  |   		|||
|   			 Cable reliability  |   			  			 20 million door movements  |   		|||
|   			 Light immunity  |   			  			 ≤100000LUX  |   		|||
|   			 EMC compliance  |   			  			 Emissions to EN12015,Immunity to EN12016  |   		|||
|   			 Operating temperature range  |   			  			 -20℃~+65℃  |   		|||
|   			 IP rating  |   			  			 IP54  |   		|||
|   			 Vibration test  |   			  			 Random vibration 20 to 500Hz 0.002g2/Hz 4hrs per axis Sinusoidal 30Hz 3.6 rms 30mins per axis  |   		|||
|   			 Response Time (NON or PNP)  |   			  			 45ms  |   			  			 65ms  |   		||
|   			 Response time (Relay)  |   			  			 60ms  |   			  			 80ms  |   		||
|   			 Timeout Function  |   			  			 15Sec 3 non-adjacent diodes  |   			  			 15Sec 5 non-adjacent diodes  |   		||
|   			 POWER SUPPLY UNIT(see detailed information in Page 31)  |   		||||
|   			 Model P220  |   			  			 Input voltage 220V AC±20% 4VA  |   		|||
|   			 Model P110  |   			  			 Input voltage 110V AC±20% 4VA  |   		|||
|   			 Model P110/220  |   			  			 Input voltage 110/220V AC(Switchable) 4VA  |   		|||
|   			 Model P110/220-W  |   			  			 Input voltage 85~265V AC(Switchable) 4VA  |   		|||
|   			 Model P12/24  |   			  			 Input voltage 10~35V DC 4VA  |   		|||
|   			 Model P24  |   			  			 Input voltage 19~36V DC 4VA;18~30V AC 4VA  |   		|||
|   			 System Hint (Buzzers are optional)Mode 1:Give buzzer sound once interrupted. Mode 2:Give buzzer sound 15 second after continuously interrupted  |   		||||
|   			 PNP/NPN (Without power supply unit)(see detailed information in Page 32)  |   		||||
|   			 Input voltage  |   			  			 15~35V DC 3VA  |   		|||
|   			 Output modes  |   			  			 PNP-N/C:High level effective,Normal output high,Interrupt output open(Invalid level)  |   		|||
|   			 Output modes  |   			  			 PNP-N/O:High level effective,Normal output open(Invalid ),Interrupt output high  |   		|||
|   			 Output modes  |   			  			 NPN-N/C:Low level effective,Nomal output low,Interrupt output open (Invalid level)  |   		|||
|   			 Output modes  |   			  			 NPN-N/O:Low Level effective ,Normal output open (Invalid level),Interrupt output low  |   		|||
|   			 Output currents  |   			  			 Maximum 500mA(Can drive small load such as relay)  |   		|||
 