3000MHz / 3G antenna surge protector for coaxial / cell sites / antenna systems

TSTLP TS-3000N 3GHz (3000 MHz) antenna surge protector,designed as per IEC 61643-21 is for protecting 50Ω coaxial feeding system at LPZ0B-1 protection.
| Model | TS-G3000N |
| Rated voltage (max. continuous voltage) | 250V |
| Nominal current | 3.5A |
| Lightning impulse current(10/350) | 1kA |
| Nominal discharge current (8/20) | 8kA |
| Max.discharge current (8/20) | 20kA |
| Voltage protection level at Imax | ≤750V |
| Frequency range | 3000MHZ |
Technical Data P2

Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the antenna surge protector.

PDF Catalog Download - TS-Antenna SPD.pdf
Tag: antenna surge protector