Ultrasonic Cross-Hole Testing System for Automatic Foundation Pile Detection
Application
- Continuous rapid testing of building foundation piles by cross-hole sonic logging
- Inspection of concrete defects by ultrasonic method, such as uncompacted, cellular, hole area and so on
- Detecting strength of concrete by ultrasonic-rebound combine method
- Detecting strength of concrete crevice by ultrasonic-rebound combine method
- Detecting defects of one hole by one trigger two receive.
- Testing mechanical properties of non-metallic material, such as rock, concrete etc.
Performance
- High efficient testing: lifting speed more than 60m/s(20cm distance).
- Display test data graphically: watch analyze result directly.
- Fast and precise automatic judge sound parameters: real-time wave display to ensure test efficiency.
- Humanized software design, apply to user and construction plant. Ensure user handle it easily.
- Linking the rebound apparatus directly, detecting strength of concrete by ultrasonic-rebound combine method with linking rebound apparatus directly, and get strength of concrete in time.
- Being sensitive to receiving signal: receive signal more than 10m in concrete without defects.
- Can supply smooth power for radial energy transducer needless external power
- Standard USB storage with big capacity
- Interior lithium battery, work more than 6 hours
- Portable, impact design and light apparatus
- extending function for testing thickness of concrete by impacting echo method
- Professional and powerful analysis software. Export the data to excel or word for advance analysis.
Technical Data
| Item |
Specification |
Item |
Specification |
| Main control unit |
high-performance embed computer |
Display |
640*480, LCD high brightness TFT |
| Input |
Keyboard |
Storage |
1G(internal)+2G(U Disk) |
| Interface |
USB |
Maximum hoisting speed |
60m/min(20cm distance) |
| Receive Channel |
Two |
Maximum sampling length |
64k |
| Trigger Mode |
Continuous trigger, external trigger |
Transmit Voltage(V) |
65, 125, 250, 500, 1000 selectable |
| Receive sensitivity |
≤30μv |
Amplifier gain |
82dB |
| Amplifier bandwidth |
5Hz~500kHz |
Sampling Interval |
0.05μs~6.4μs |
| Phonatory time accuracy |
0.05μs |
amplitude resolution |
0.39% |
| Power |
Interior lithium battery, more 6hours |
Connect concrete hammer |
YES |
| (optional) external lithium battery, more than 6hours |
Dimension of Frame |
260 mm*185 mm*60 mm |
| DC 12V |
Weight |
1.75 |
| AC 100V-240V, 50/60Hz |
Work temperature |
—10 to +40 degree |
Standard Packing List