Walk in chamber for Complex Salt Spray Test / Temperature controllable
Standard
UL 2580
Relevant standards requirement
Test Object: battery pack and system.
Refer GB/T4 part 5.5.2 test method, test according to GT/T2423.17 test conditions.
The salt solution was made up of sodium chloride (chemically pure and analytically pure) and distilled or deionized water,Its concentration is (5 + 1)% (mass fraction).
(35 ± 2) ℃, the measured pH value is between 6.5-7.2.
Placed the test objects in the salt spray chamber for the cycling test. Each cycling duration for 24h. Spray salt solution to the test object for 8 hours under the temperature of (35± 2) ℃, remain for 16 hours. Between the fourth and the fifth hour in one cycle should be according to test requirement in GB/T 28046.1-2011, test mode with 3.2.
Total 6 cycles of testing.
Salt spray test is not necessary for the test objects being installed in passenger, luggage, or cargo compartments.
Technical Parameters
| Product Name | Complex Salt Spray Test Chamber | |
| Model No. | BE-8209-12m³ | BE-8209-15m³ |
| Internal Dimension | W2000 X D3000 X H2000 mm | W2500 X D3000 X H2000 mm |
| External Dimension | W2400 X D5000 X H3000 mm | W2900 X D5000 X H3000 mm |
| Max Load | 1000KG for battery pack | |
| Temp. Range | 0℃~+85℃ | |
| Temp. Fluctuation | ±0.5℃ | |
| Temp. Deviation | 2℃ | |
| Spray Capacity | 1~2mL/80cm2/hr (Collect at least 16 hours, take the average ) | |
| Spray Pressure | 1.00±0.01kgf/cm² | |
| Resolution | Temp: 0.01℃, Humidity:0.01%R.H. | |
| Humidity Range |
| |
| Humidity Fluctuation | ±3%R.H. | |
| Potion PH | Neutral 6.0~7.0 Acidity 3.0~3.1 | |
| Spray Solution PH | Neutral 6.5~7.2 Acidity 3.1~3.3 | |
| Test Time Range | 1S ~ 9999H (Settable) | |
| Control Mode | Touch screen programmable control PLC, networking; mobile phone APP alarm; with USB interface, with RJ485 interface can be connected to computer control, exclusive network control software. Remote monitoring and data acquisition. | |
| Internal material | Acid and alkali resistant SUS316 material | |
| External material | Cold and heat resistant steel plate with spray coating | |
| Cooling Mode | Air cooling / water cooling | |
| Total Weight | Approx 7 Tons | |
| Power Supply | AC 380V, 55KW | |
| Other Auxiliary Functions | *Main-subsidiary type trolley for the specimen in and out of the test chamber.*Explosion-proof, Pressure relief, Smoke Exhaust, Fire extinguishing, Video monitoring. | |