| Output | Output Max. | Power Max. | DOE VI |
| (V) | (A) | (W) | |
| 12V | 1.5A | 18W | √ |
| 24V | 0.75A | 18W | √ |

| Input Voltage Range | 100-240Vac 50/60Hz |
| Input Current(Max) | 2.5A |
| Temperature Coefficient | ±0.05%/℃ |
| Voltage Accuracy | ±2% |
| Total Regulation | ±5% |
| Ripple & Noise | 120mV |
| Short Circuit Protection | Continuous - hiccup mode |
| Over Voltage Protection | 110-150% of nominal (Cycle input power to reset) |
| Efficiency at Average Load | 88% min |
| Operation Temperature | 0 to +60℃, derating linearly to 50% load above 40℃ |
| Storage Temperature | -10 to +85℃ |
| Humidity (non condensing) | 10-90% RH |
| Cooling | Convection |
| Withstand Voltage | Input to Ground 1.5kVAC |
| Input to Output 3kVAC | |
| (Output is connected to Ground) | |
| Vibration (non condensing) | 23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour) |
| Shock | < 196.1 m/s2 (20G) |
| Safety Agency Certifications | UL62368,UL1310,UL60950-1, EN609501-1, IEC60950-1, CE Mark |
| DOE Regulation | VI |
| Off-Load Power Consumption | <210mV |
| Conducted & Radiated EMI | EN55023-B, FCC Class B |
| Immunity | EN55024 |

| Power | Output | Output | AC Type |
| Voltage | Current | ||
| 18W Series | 0-6.0V | 0-3.0A | Desktop |
| 7-12.0V | 0-1.5A | Wall-mounted | |
| 13-18.0V | 0-1.0A | Interchangeable | |
| 19-25.0V | 0-0.75A | ||
| 26-30.0V | 0-0.6A | ||
| Remark: | |||
| 1.Model NO : YHY-XXXYYYYY , "XXX" is for current "YYYYY" is for voltage | |||
| 2.Input :100-240Vac , 50-60Hz , 2.5A max. | |||