Gustav Elevator Rope With Fiber Core Particularly Suitable For Softer Traction Sheaves
Elevator rope with fiber core
This rope is used in many standard elevators and has a proven history both in Europe and many other countries worldwide. Because of the dual tensile grade of the wires in the strands, this type may be used on softer traction sheaves. Thus, the hardness ratio rope/sheave is shifted towards the sheave.
Particularly for North America, you will find an even lower tensile grade of just 1180 N/mm2 outer strand hardness. See separate 4th Edition catalogue of Elevator Ropes for North America which you can also download.
Properties
- particularly suitable for softer traction sheaves
- excellent service life
- light and flexible
Construction: 8 x 19 Seale with fiber core, regular lay
technical terms of delivery to DIN EN 12385, ISO 4344; BS 302-4
load bearing wires in the outer strands: 152
rope-Ø (permissible tolerance) |
|
no load: |
with load (10% of Fmin): |
max. 6% < 10 mm |
min. -0% <= 10 mm |
max. 5% > 10 mm |
min. -0% > 10 mm |
rope diameter (mm) |
calculated mass (kg/m) |
min. breaking load (kN) |
part-no. |
8 |
0,22 |
30,5 |
621108011 |
9* |
0,28 |
38,4 |
621109011 |
10 |
0,35 |
48,2 |
621110011 |
11 |
0,43 |
58,4 |
621111011 |
12 |
0,5 |
69,2 |
621112011 |
13 |
0,59 |
80,7 |
621113011 |
14* |
0,68 |
93 |
621114011 |
15* |
0,78 |
108 |
621115011 |
16 |
0,89 |
121 |
621116011 |
18 |
1,11 |
154 |
621118011 |
19* |
1,26 |
171 |
621119012 |






FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.