DBETE-52/50G24K31A1V Proportional valve German Rexroth overflow valve
|
|
|
Specification / Description
|
|
|
|
DBETE (Proportional Pressure Control Valve, likely a relief or reducing valve)
|
|
|
|
52 (Indicates the nominal size or port size of the valve)
|
|
|
|
50 bar (Indicated by "/50" in the model number)
|
|
|
|
24 V DC (Indicated by "G24" in the model number)
|
|
|
|
K31 (Specifies the type of electrical connector)
|
|
|
|
A1V (Likely indicates a specific control function, e.g., voltage input signal (0-10V))
|
|
|
Maximum Operating Pressure
|
315 bar (A common maximum pressure rating for valves in this series)
|
|
|
Hydraulic Fluid Compatibility
|
Mineral-based hydraulic oils (e.g., HL, HLP as per DIN 51524)
|
|
|
|
Likely ISO 4401 standard (Common for industrial hydraulic valves)
|

| 0811402017 DBETX-1X/180G24-8NZ4M |
| 0811402019 DBETX-1X/250G24-8NZ4M |
| 0811402016 DBETX-1X/315G24-8NZ4M |
| 0811402034 DBETX-1X/50G24-25NZ4M |
| 0811402030 DBETX-1X/80G24 25NZ4M |
| 0811402031 DBETX-1X/180G24-25NZ4M 111 |
| 0811402035 DBETX-1X/250G24-25NZ4M |
| 0811402032 DBETX-1X/315G24-25Z4M |
| 0811402013 DBETBX-1X/28G24-37Z4M |
| 0811402007 DBETBX-1X/80G24-37Z4M2 |
| 0811402003 DBETBX-1X/180G24-37Z4M |
| 0811402001 DBETBX-1X/250G24-37Z4M2 |
| 0811402004 DBETBX-1X/315G24-37Z4M |
| DBETX-1X/50G24-8NZ4M |
| DBETX-1X/80G24-8NZ4M |
| DBETX-1X/315G24-8NZ4M |
| DBETX-1X/180G24-8NZ4M |
| DBETX-1X/250G24-8NZ4M |
| DBETX-1X/80G24-25NZ4M |
| DBETX-1X/50G24-25NZ4M |
| DBETX-1X/180G24-25NZ4M |
| DBETX-1X/315G24-25NZ4M |
| DBETX-1X/250G24-25NZ4M |
| DBET-61/50YG24K4M |
| DBET-61/50YG24K4V |
| DBET-61/100YG24K4M |
| DBET-61/100YG24K4V |
| DBET-61/200YG24K4M |
| DBET-61/200YG24K4V |
| DBET-61/315YG24K4M |
| DBET-61/315YG24K4V |
| DBET-61/350YG24K4M |
| DBET-61/350YG24K4V |
| DBETE-6X/420YG24K31A1V |
| DBETE-6X/50G24K31A1V |
| DBETE-6X/50G24K31F1V |
| DBETE-6X/50YG24K31A1V |
| DBETBX-1X/80G24-37Z4M2 |
| DBETBX-1X/250G24-37Z4M2 |
| DBETBEX-1X/80G24k31A1M |
| DBETBEX-1X/180G24k31A1M |
| DBETBEX-1X/250G24k31A1M |
| DBETBEX-1X/315G24k31A1M |
| DBETBEX-1X/80G24k31F1M |
| DBETBEX-1X/180G24k31F1M |
| DBETBEX-1X/315G24k31F1M |
| DBEP6A06-1X/45AG24K4M |
| DBEP6B06-1X/45AG24K4M |
| DBEP6C06-1X/45AG24K4M |
| DBEBE6X-1X/180G24K31F1M |
| DBEBE6X-1X/80G24K31A1M |
| DBEBE6X-1X/180G24K31A1M |
| DBEBE6X-1X/315G24K31A1M |
| DBETR-1X/30G24K4M |
| DBETR-1X/80G24K4M |
| DBETR-1X/180G24K4M |
| DBETR-1X/230G24K4M |
| DBETR-1X/315G24K4M |
| DBETR-1X/350G24K4M |
| DBET-52/50G24K4M |
| DBETE-52/100G24K31F1M |
| DBETE-52/350G24K31F1M |
| DBETE-52/350G24K31A1V |
| DBETE-52/350G24K31A1M |
DBETE-52/50G24K31A1V - Frequently Asked Questions (FAQ)
1. What is the operating voltage and current requirement?
Q: What are the electrical specifications for this valve?
A: The DBETE-52/50G24K31A1V operates on 24V DC (G24) power supply. The typical current consumption is 0.8A to 1.0A. Ensure the power supply is stable and within ±10% tolerance for reliable operation.
2. What is the maximum working pressure?
Q: What pressure rating does this valve have?
A: This model has a maximum working pressure of 50 bar (as indicated by "/50" in the model number). Do not exceed this pressure limit to prevent valve damage or system failure.
3. What type of control signal does it accept?
Q: How is the pressure setting controlled?
A: The "A1V" in the model number indicates it accepts a 0-10V voltage input signal for proportional pressure control. Ensure the control signal is clean, properly shielded, and free from electrical noise.
4. What hydraulic fluid is compatible?
Q: Which hydraulic oils can be used with this valve?
A: The valve is compatible with standard hydraulic oils including HL, HLP, HVLP types. Maintain fluid cleanliness to ISO 18/16/13 or better. Operating temperature range is typically -20°C to +80°C.
5. How to troubleshoot if the valve doesn't respond?
Q: What should I check if the valve doesn't adjust pressure with the input signal?
-
24V DC power supply is present and stable
-
Control signal (0-10V) is within range and properly connected
-
Hydraulic fluid is clean and at proper level
-
Check electrical connections for corrosion or loose wires
-
If issues persist, the integrated electronics may require service