Stator Testing Machine Of Shaded-Pole Motor / Automatic Stator Tester
1. Product features:
2. Technical parameters
| DC winding resistance | ||
| measuring range and precision | 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set | |
| test time range/resolution |  			 0.5~999s 0.1s/step  |  		|
| temperature probe/measuring range | -10.0℃~+50.0℃ | |
| measuring precision | ±0.5°C(range: -10℃~+50℃) | |
| temperature compensation | Yes | |
| Rotation | ||
| Direction of rotation | CW/CCW/still | |
| Surge | ||
| sampling frequency | 100MHz | |
| output voltage setting range/precision | 500~3000V ±(3%×display value+8V) | |
| waveform comparison |  			 area, area difference, corona, phase three waveforms will be displayed on the testing interface  |  		|
| AC Hipot | ||
| output voltage setting range/precision | AC 200~3000V ±(1.5%×setting value+10V) | |
| breakdown current presetting alarm range | Max: 0.10~20.00mA; Min: 0.00~20.00mA | |
| breakdown current measuring range | 0.10~20.00mA ±(2%×display value +0.05mA) | |
| test time range/resolution | 0.5~999.9s 0.1s/step | |
| Insulation resistance | ||
| output voltage setting range/precision | DC 500V/1000V ±(1.5%×setting value+10V) | |
| test time range/resolution | 0.5~999.9s 0.1s/step | |
| insulation resistance testing range/precision |  			 1~500MΩ ≤100MΩ:±(3%×display value+0.5MΩ); >100 MΩ:±(5%×display value+5MΩ)  |  		|
| insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~500MΩ | |