1600A FSMC Waterproof Cast Resin Bus Duct Insulated Customized
Manufacturer customized 1600A FSMC waterproof casting type bus duct insulated resin Busduct System
We offer a comprehensive range of busbar trunking products and can develop tailored solutions to meet your specific requirements. Contact us via email or WhatsApp for personalized assistance. We wish you productive work and a fulfilling life!
Dense Bus Duct Selection Parameters
| Current Level |
XLC /4P W(mm) |
XLC /4P H(mm) |
XLC /5P W(mm) |
XLC /5P H(mm) |
| 400 | 128 | 98 | 128 | 98 |
| 500 | 128 | 108 | 128 | 108 |
| 630 | 128 | 123 | 128 | 123 |
| 800 | 128 | 138 | 128 | 138 |
| 1000 | 128 | 158 | 128 | 158 |
| 1250 | 128 | 183 | 128 | 183 |
| 1600 | 128 | 218 | 128 | 218 |
| 2000 | 128 | 268 | 128 | 268 |
| 2500 | 128 | 280 | 128 | 280 |
| 3200 | 128 | 400 | 128 | 400 |
| 4000 | 128 | 490 | 128 | 490 |
XLC Type Bus Duct Technical Parameters
| Execution Standards | IEC60439.1-2000 IEC60439.2-2000 GB/T 7251.6-2015 |
| Ambient Temperature | -5/+40°C (24-hour average temperature not exceeding 35°C) |
| Altitude | Not exceeding 2000M |
| Protection Grade | IP54, IP66 |
| Unit Length (M) | Choose between 1.6, 2.5, 3.2, 6 (0.5-6) |
| Rated Operational Voltage (V) | 690V (with tap unit)/1000V (without tap unit) |
| Rated Insulation Voltage (Ui) (V) | 800V (with tap unit)/1000V (without tap unit) |
| Frequency (HZ) | 50-60 |
| Temperature Rise (K) | ≤70 |
| Insulation Resistance (MΩ) | ≥20 |
| Electrical Clearance (mm) | ≥ 10.0mm (with tapping unit)/≥ 14.0mm (without tapping unit) |
| Creepage (mm) | ≥ 12.5mm (with tap cell)/≥ 16.0mm (without tap cell) |
| Protection Circuit Effectiveness (Ω) | <0.02 |
| Dielectric Properties | 50Hz, 3750v/min, no breakdown, flashover |
| Installation Method | Vertical or horizontal |
| Number of Plug-in Interfaces | Minimum 0.5/m pieces (double-sided plug can be provided) |
Electrical Performance Specifications
| Rated Current (A) |
Resistance (uΩ/m) |
Reactance (uΩ/m) |
Total Reactance (uΩ/m) |
Voltage Drop (mV/m) |
Rated Short-time Withstand Current (KA) |
Rated Peak Withstand Current (KA) |
Maximum Fixed Spacing (m) |
Balanced Load (kg/m) |
Concentrated Load (kg) |
| 400 | 88.9 | 66.5 | 289.7 | 77.5 | 30 | 63 | 4 | 20 | 90 |
| 630 | 71.1 | 62.2 | 289.7 | 81 |
| 800 | 56.4 | 39.1 | 184.2 | 77.3 | 50 | 105 | 3 | 20 | 90 |
| 1000 | 40.3 | 37.9 | 176.3 | 77.5 |
| 1250 | 33.2 | 46.6 | 221.6 | 76.4 | 80 | 176 | 3 | 25 | 90 |
| 1600 | 24.5 | 30.1 | 150.7 | 74.9 |
| 2000 | 19.5 | 7.4 | 130.7 | 73.3 |
| 2500 | 14.5 | 25.9 | 129.6 | 71.4 | | | | | |
| 3150 | 11.3 | 25.3 | 120.9 | 69.7 | | | | | |
| 4000 | 8.9 | 14.3 | 76.2 | 63 | | | | | |
| 5000 | 6.7 | 13 | 69 | 61.4 | | | | | |